Instrument parameters controlling retention precision in gradient elution reversed-phase liquid chromatography

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High speed gradient elution reversed-phase liquid chromatography.

A major disadvantage of gradient elution in terms of speed results from the need to adequately re-equilibrate the column. This work distinguishes two states of re-equilibration: (1) run-to-run repeatability and (2) full equilibration. We find that excellent repeatability (+/-0.002 min in retention time) is achieved with at most 2 column volumes of re-equilibration whereas full equilibration can...

متن کامل

Retention modelling in ternary solvent-strength gradient elution reversed-phase chromatography using 30 mm columns.

An optimization strategy for ternary solvent-strength gradient elution RP chromatography is described in which a two-dimensional model of gradient time (2 levels) against ternary proportions of organic modifiers (4 levels) was constructed. From the resolution surface the optimum ratio of organic modifiers could be selected. Excellent retention time and acceptable peak width and resolution simul...

متن کامل

New approach to linear gradient elution used for optimisation in reversed-phase liquid chromatography.

A new mathematical treatment concerning the gradient elution in reversed-phase liquid chromatography when the volume fraction psi of an organic modifier in the water-organic mobile phase varies linearly with time is presented. The experimental ln k versus psi curve, where k is the retention factor under isocratic conditions in a binary mobile phase, is subdivided into a finite number of linear ...

متن کامل

Retention mechanism, isocratic and gradient-elution separation and characterization of (co)polymers in normal-phase and reversed-phase high-performance liquid chromatography.

Synthetic (co)polymers or (co)oligomers with two (or more) repeating groups show not only molar mass distribution, but also composition and sequence distribution of the individual repeat units. To characterize such two- (or more-) dimensional distribution, liquid chromatography under "critical conditions" has been suggested, where the separation according to one type of repeating units is suppr...

متن کامل

Choice of Model for Estimation of Adsorption Isotherm Parameters in Gradient Elution Preparative Liquid Chromatography

The inverse method is a numerical method for fast estimation of adsorption isotherm parameters directly from a few overloaded elution profiles and it was recently extended to adsorption isotherm acquisition in gradient elution conditions. However, the inverse method in gradient elution is cumbersome due to the complex adsorption isotherm models found in gradient elution. In this case, physicoch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Chromatography A

سال: 2014

ISSN: 0021-9673

DOI: 10.1016/j.chroma.2014.09.085