Instrumented Impact Testing of Ceramics
نویسندگان
چکیده
منابع مشابه
Instrumented Indentation Testing
INSTRUMENTED INDENTATION TESTING (IIT), also known as depth-sensing indentation, continuous-recording indentation, ultra-low-load indentation, and nanoindentation, is a relatively new form of mechanical testing that significantly expands on the capabilities of traditional hardness testing. Developed largely over the past two decades, IIT employs high-resolution instrumentation to continuously c...
متن کاملInstrumented Fuzz Testing Using AIR Integers
Integers represent a growing and underestimated source of vulnerabilities in C and C++ programs. In this paper, we present the as-if infinitely ranged (AIR) integer model, which provides a largely automated mechanism for eliminating integer overflow, truncation, and other integral exceptional conditions. The AIR integer model either produces a value equivalent to one that would have been obtain...
متن کاملInstrumented Fuzz Testing Using AIR Integers (Whitepaper)
Integers represent a growing and underestimated source of vulnerabilities in C and C++ programs. In this paper, we present the as-if infinitely ranged (AIR) integer model, which provides a largely automated mechanism for eliminating integer overflow, truncation, and other integral exceptional conditions. The AIR integer model either produces a value equivalent to one that would have been obtain...
متن کاملTransient forces generated by projectiles on variable quality mouthguards monitored by instrumented impact testing.
OBJECTIVES (a) To determine the force-time trace that occurs when a spring mounted simulated upper jaw is impacted; (b) to examine if mouthguards of variable quality have significant influence on such force-time traces; (c) to attempt to relate physical events to the profile of the force-time traces recorded. METHODS A simulated jaw, consisting of ceramic teeth inserted into a hard rubber arc...
متن کاملKyphotic Angles of Instrumented Thoracolumbar Junction: Impact of Thoracolumbosacral Orthosis
Introduction: Bracing is an accepted part of operative treatment, however; the effectiveness of bracing is controversial. We sought evidences for the effect of Thoracolumbosacral Orthosis (TLSO) on spine proximal to the fusion site in patients treated for unstable thoracolumbar junction (TLJ) burst fractures. Materials and Methods: Fifty adult patients with unstable TLJ burst fractures are pros...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Japan Institute of Metals
سال: 1986
ISSN: 0021-4434,2432-4701
DOI: 10.2320/matertrans1960.27.775