Intensity warping for multisite MRI harmonization
نویسندگان
چکیده
منابع مشابه
Ultrasound/MRI Overlay with Image Warping for Neurosurgery
Performing a craniotomy will cause brain tissue to shift. As a result of the craniotomy, the accuracy of stereotactic localization techniques is reduced unless the brain shift can be accurately measured. If an ultrasound probe is tracked by a 3D optical tracking system, intraoperative ultrasound images acquired through the craniotomy can be compared to pre-operative MRI images to quantify the s...
متن کاملInter-site and inter-scanner diffusion MRI data harmonization
We propose a novel method to harmonize diffusion MRI data acquired from multiple sites and scanners, which is imperative for joint analysis of the data to significantly increase sample size and statistical power of neuroimaging studies. Our method incorporates the following main novelties: i) we take into account the scanner-dependent spatial variability of the diffusion signal in different par...
متن کاملMethod for Estimating the Intensity Mappingbetween MRI
A method is presented for determining the intensity mapping between MRI images that may have been acquired using diierent sequences or instruments. The method can be applied to fully elastic matching and produces spatially localized probability functions that are capable of representing in an eecient way strong intensity distortions due, for instance, to the shading eeect in MRI.
متن کاملSOM for intensity inhomogeneity correction in MRI
Given an appropriate imaging resolution, a common Magnetic Resonance Imaging (MRI) model assumes that object under study is composed of piecewise constant materials, so that MRI produces piecewise constant images. The intensity inhomogeneity (IIH) is modeled by a multiplicative inhomogeneity field. It is due to the spatial inhomogeneity in the excitatory Radio Frequency (RF) signal and other ef...
متن کاملWhole Body MRI Intensity Standardization
A major problem of segmentation of magnetic resonance images is that intensities are not standardized like in computed tomography. This article deals with the correction of inter volume intensity differences that lead to a missing anatomical meaning of the observed gray values. We present a method for MRI intensity standardization of whole body MRI scans. The approach is based on the alignment ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: NeuroImage
سال: 2020
ISSN: 1053-8119
DOI: 10.1016/j.neuroimage.2020.117242