Internal fixation of fractures of the ulna with bio-absorbable implants. Later results

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique

Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...

متن کامل

Functional Outcome of Internal Fixation of Radial and Ulna Fracture

Background: Displaced fractures of radius and ulna bones in adults are usually treated with open reduction and internal fixation. The purpose of this research was to access functional outcome of these fractures. Materials and Methods: In this research 52 Patients who underwent ORIF with DCP 3.5 in past 5 years were investigated. Post-operation protocol was one week immobilization and then acti...

متن کامل

DISPLACED- COMMINUTED INTRAARTICULAR FRACTURES OF THE ADULT DISTAL HUMERUS: FUNCTIONAL RESULTS AFTER INTERNAL FIXATION

Background: Intra-articular T- type or Y- type fractures of the distal end of the humerus are relatively rare, and consequently few surgeons will be able to attain extensive experience with the surgical treatment of these injuries. The current emphasis is on operative intervention with rigid internal fixation and early mobilization. Methods: In this prospective and retrospective study, we r...

متن کامل

Bio-Environment-Induced Degradation and Failure of Internal Fixation Implants.

Internal fixations provide fast healing but their failure remains problematic to patients. Here, we report an experimental study in failure of three typical cases of metals: a bent intramedullary stainless steel nail, a broken exterior pure Ti plate, and a broken intramedullary stainless steel nail. Characterization of the bent nail indicates that those metals are vulnerable to corrosion with t...

متن کامل

Impact response and simulation of damaged ulna with internal fixation.

The objectives of this work were to explore a methodology that combines static and dynamic finite element (FE) analysis, linear elastic fracture mechanics (LEFM) and experimental methods to investigate a worst-case scenario in which a previously damaged bone plate system is subjected to an impact load. Cadaver ulnas with and without midshaft dynamic compression plates are subjected to a static ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Frontiers in Pharmacology

سال: 2010

ISSN: 1663-9812

DOI: 10.3389/conf.fphar.2010.60.00097