Internal headless compression screw method for 4-corner fusion

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Four-corner arthrodesis using two headless compression screws.

We present the outcome of four-corner wrist arthrodesis using two headless compression screws for fixation. The study group consisted of 27 patients who underwent arthrodesis from 1998 through 2007. Data on demographic parameters, diagnosis, range of motion, pain and complications were collected from the medical files. A total of 77 series of anteroposterior, oblique, and lateral x-rays were re...

متن کامل

Insertion profiles of 4 headless compression screws.

PURPOSE In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. METHODS The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaph...

متن کامل

Physeal-sparing tibial eminence fracture fixation with a headless compression screw.

Displaced tibial intercondylar eminence fractures frequently require operative fixation. Surgical techniques for fixation include the use of headed screws or sutures. However, these fractures commonly occur in skeletally immature patients, and current techniques violate the proximal tibial physis to maintain reduction and can result in growth disturbances. The authors present a physeal-sparing ...

متن کامل

An Unexpected Complication after Headless Compression Screw Fixation of an Osteochondral Fracture of Patella.

This study evaluated complications associated with implant depth in headless compression screw treatment of an osteochondral fracture associated with a traumatic patellar dislocation in a 21-year-old woman. Computed tomography and X-rays showed one lateral fracture fragment measuring 25 × 16 mm. Osteosynthesis was performed with two headless compression screws. Five months later, the screws wer...

متن کامل

Tibiotalocalcaneal arthrodesis with headless compression screws

BACKGROUND Tibiotalocalcaneal arthrodesis with headless compression screws has not been previously reported. We hypothesized that these screws could be suitable for tibiotalocalcaneal arthrodesis because of their special design. This study aimed to evaluate the clinical outcomes of patients undergoing tibiotalocalcaneal arthrodesis with headless compression screws for the treatment of severe ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Hand and Microsurgery

سال: 2016

ISSN: 0974-3227,0974-6897

DOI: 10.1007/s12593-009-0008-5