Intra-operative error during Austin Moore hemiarthroplasty.

PURPOSE To examine the frequency of technical errors during implantation of the Austin Moore prosthesis in a public hospital. METHODS Radiographs and charts of 147 consecutive uncemented Austin Moore hemiarthoplasty patients were retrospectively reviewed with particular reference to intra-operative errors associated with early failure of the prosthesis. RESULTS 48% of the patients had at le...

متن کامل

Intra-operative fractures in cementless bipolar hemiarthroplasty.

PURPOSE To compare patients with or without intra-operative fracture during cementless bipolar hemiarthroplasty. METHODS Records of 76 men and 202 women who underwent cementless bipolar hemiarthroplasty for femoral neck fractures were reviewed. Patients with and without intra-operative fractures and patients with different types of intra-operative fractures were compared. RESULTS Two men an...

متن کامل

Is It Time to Phase Out the Austin Moore Hemiarthroplasty? A Propensity Score Matched Case Control Comparison versus Cemented Hemiarthroplasty

We compared the Austin Moore hemiarthroplasty versus cemented hemiarthroplasties using a propensity score matched cased control study. For a consecutive cohort of 450 patients with displaced intracapsular neck of femur fractures, 128 matched cases in each group were selected based on age, gender, walking status, nursing home residency, delays in surgery, ASA score, and the Charlson comorbidity ...

متن کامل

The effect of laminar air-flow on the results of Austin-Moore hemiarthroplasty.

INTRODUCTION A second cycle audit to evaluate the results after introduction of water impervious surgical gowns and drapes while performing Austin-Moore hemiarthroplasty as recommended by our previously published study. AIM To assess the difference in the re-operation rate following Austin-Moore hemiarthroplasty between procedures performed under laminar air-flow to those performed in convent...

متن کامل

Intraoperative Periprosthetic Femoral Fractures Related to Austin Moore Hemiarthroplasty—A Retrospective Review of 365 Patients

Intraoperative periprosthetic femoral fractures (IPFF) have been studied extensively for total hip arthroplasties, but not for hemiarthroplasties. Recent series in the literature show an IPFF rate for hemiarthroplasties ranging from 0% to 14%. The present study was designed to determine the prevalence and outcome after IPFF during non-cemented hemiarthroplasty. In addition, the surgical step at...

متن کامل