Intraaortic balloon counterpulsation as a temporary support measure in decompensated critical aortic stenosis
نویسندگان
چکیده
منابع مشابه
Intraaortic Balloon Counterpulsation
After his first acute myocardial infarction, a 69-year-old male suffered the usually lethal complication of ventricular free-wall rupture. Early suspicion of possible rupture and immediate percutaneous insertion of an intraaortic balloon pump assist device afforded sufficient hemodynamic stability to proceed with cardiac catheterization. The diagnosis of ventricular free-wall rupture was confir...
متن کاملIntraaortic balloon counterpulsation in a community hospital.
Our experience with intraaortic balloon counterpulsation in 41 patients documents the feasibility of a coordinated aggressive therapeutic approach in patients with potentially fatal complications of coronary artery disease. The use of intraaortic balloon pump in a non-cardiac surgical center has allowed hemodynamic support in the critically ill, safety in angiography, appropriate selection of p...
متن کاملThe Effect of Intraaortic Balloon Counterpulsation
required for relief of myocardial ischemia. IABP decreased the rate7pressure product and aortic enddiastoliczpressure, and the peak systolic aortic pressure and regional myocardial oxygen consumption declined inall but one patient. Peak and mean aortic diastolic pressures increased. Changes in regional coronary blood flow paralleled changes in peak systolic aortic pressure (r = 0.92, p < 0.007)...
متن کاملParaplegia associated with intraaortic balloon pump counterpulsation.
Two patients developed paraplegia associated with the use of the intraaortic balloon pump. In one patient, transient spinal ischemic episodes ceased after removal of the intraaortic balloon and the second patient apparently sustained spinal cord infarction. Possible etiologic mechanisms include vascular occlusion due to balloon position, arterial spasm, thromboembolic phenomena, hypotension, hy...
متن کاملBalloon aortic valvuloplasty under temporary mechanical circulatory support as a bridge to aortic valve replacement in a patient with hemodynamic failure secondary to critical aortic valve stenosis.
Aortic valve replacement in the setting of critical aortic valve stenosis with cardiogenic shock is associated with high mortality, yet surgery is the only definitive treatment. We present the case of a patient with critical aortic valve stenosis and cardiogenic shock who received a short period of percutaneous mechanical support and balloon aortic valvuloplasty that resulted in rapid clinical ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American College of Cardiology
سال: 1985
ISSN: 0735-1097
DOI: 10.1016/s0735-1097(85)80399-5