Intraaortic balloon pumping.
نویسندگان
چکیده
منابع مشابه
Understanding intraaortic balloon pumping.
Nurses are accountable for their care. Understanding the physiology and process behind any intervention improves patient care, while also increasing nursing satisfaction and skill and IABP is no exception. An awareness of IABP will facilitate sound nursing care, ensure early identification of possible complications or patient compromise, and lead to patient and relative satisfaction. It will al...
متن کاملIntraaortic Balloon Pumping for Ventricular Septal Defect
The intraaortic balloon pump (IABP) has been employed in the management of five patients with ventricular septal rupture (VSD) and six patients with acute mitral regurgitation (AMR) following myocardial infarction. All patients were in cardiogenic shock which responded poorly to medical therapy including pressor and inotropic agents. IABP resulted in significant clinical and hemodynamic improve...
متن کاملEarly intraaortic balloon pumping for anterior myocardial infarction without shock.
Eleven patients with anterior myocardial infarction less than six hours old underwent intraaortic balloon pumping (IABP) in an attempt to control injury. Direct hemodynamic measurements excluded shock. Response to therapy was judged individually by comparison to a one-hour pretreatment period. There was no parallel control group. Five patients responded with an 84% fall in ST elevation in one h...
متن کاملIntraaortic balloon pumping for control of recurrent myocardial ischemia.
Eleven patients were studied because of recurrent angina at rest. In five cases ischemic pain developed 3-10 days after acute myocardial infarction. Pain recurred in all cases despite therapy with bedrest, oxygen, heparin anticoagulation, nitrates, and whenever possible, beta blockade. Intraaortic balloon pumping with a 30-cc balloon prevented ischemia in nine patients and markedly reduced the ...
متن کاملIntraaortic Balloon Counterpulsation
After his first acute myocardial infarction, a 69-year-old male suffered the usually lethal complication of ventricular free-wall rupture. Early suspicion of possible rupture and immediate percutaneous insertion of an intraaortic balloon pump assist device afforded sufficient hemodynamic stability to proceed with cardiac catheterization. The diagnosis of ventricular free-wall rupture was confir...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Circulation
سال: 1978
ISSN: 0009-7322,1524-4539
DOI: 10.1161/circ.58.6.361278