Intramedullary Cancellous Screw Fixation of Simple Olecranon Fractures
نویسندگان
چکیده
منابع مشابه
Clinical results of the re-fixation of a Chevron olecranon osteotomy using an intramedullary cancellous screw and suture tension band
Exposure of the distal humerus in case of an articular fracture is often performed through a Chevron osteotomy of the olecranon. Several options have been described for re-fixation of the Chevron osteotomy. Pull-out of the hard-wear is often seen as complication. In this study, an evaluation of the re-fixation of the Chevron osteotomy through a cancellous screw and suture tension band was perfo...
متن کاملCannulated cancellous screw fixation for capitellum fractures in adolescents.
PURPOSE To review the outcome of 9 adolescents treated with 2 to 3 cannulated cancellous screws for type-1 capitellum fractures. METHODS Records of 8 boys and one girl aged 12 to 14 (mean, 14) years with type-1 capitellum fractures were reviewed. The mechanism of injury was a fall on the flexed elbow. No patient had associated injuries or neurovascular compromise. In 2 patients, the fracture ...
متن کاملIntramedullary screw fixation of proximal fifth metatarsal fractures in athletes
OBJECTIVE The purpose of this study was to review the short- and long-term clinical and radiological results of intramedullary compression screw fixation of proximal fifth metatarsal fractures in athletes. METHODS Eleven male and six female active patients with fifth metatarsal zone II and zone III fractures fixed with a 4.5-mm cannulated compression screw were evaluated by chart review, revi...
متن کاملMethods of Fixation of Olecranon Fractures
This study was designed to compare the rigidity of the more commonly used techniques of internal fIxation of fractures of the olecranon. Cadaveric elbow joints were mounted in a jig and confrolled osteotomies performed to simulate transverse, oblique or comminuted fractures. Five techniques of internal fixation were tested by measuring movement at the fracture site after applying a bending mome...
متن کاملCannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
Purpose. To compare the compressive strength of cannulated versus non-cannulated cancellous screws for undisplaced femoral neck fractures in synthetic bones. Methods. 18 synthetic proximal femurs simulating an AO B1 valgus impacted femoral neck fracture in osteoporotic bone were used. The fracture angles were between 55o and 63o (Pauwels grade 2). Fixation was made using 6.5-mm non-cannulated s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Strategies in Trauma and Limb Reconstruction
سال: 2019
ISSN: 1828-8936,1828-8928
DOI: 10.5005/jp-journals-10080-1435