Intraocular pressure and biomechanical corneal properties measure by ocular response analyser in patients with primary congenital glaucoma

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of corneal biomechanical properties and intraocular pressure with the Ocular Response Analyzer in childhood myopia.

BACKGROUND/AIMS The authors estimated the association between corneal biomechanical properties and axial length in myopic children and verified the relationship between axial length and intraocular pressure (IOP). METHODS This cross-sectional study included 126 eyes of 63 children, aged 12.02+/-3.19 years. Corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CC...

متن کامل

measurement of intraocular pressure using schiotz vs tono-pen tonometers in patients with primary congenital glaucoma

purpose: to compare the tono-pen and schiotz tonometers in measurement of intraocular pressure (iop) in patients with primary congenital glaucoma. methods: this study was conducted on 38 eyes of 20 patients with primary congenital glaucoma. all measurements were performed under general anesthesia. one minute after receiving halothane 3% iop was determined by tono-pen and then by schiotz tonomet...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer.

PURPOSE The Ocular Response Analyzer (ORA) proposes to measure corneal biomechanical properties in vivo by monitoring and analyzing the corneal behavior when this structure is submitted to a force induced by an air jet. The purpose of this study was to evaluate the relationship between corneal biomechanical properties and corneal-compensated intraocular pressure (IOPCC) measurements as obtained...

متن کامل

[Effectiveness of trabeculectomy trabeculotomy in the reduction of intraocular pressure in patients with primary congenital glaucoma].

OBJECTIVE To evaluate the effectiveness of trabeculectomy trabeculotomy in the reduction of intraocular pressure in patients with primary congenital glaucoma. MATERIAL AND METHODS A pre-experimental before and after study was conducted with several measurements after; patients with intraocular pressure≥21 mmHg were included, of both sexes, and children under six years, which had ​​the trabecu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Acta Ophthalmologica

سال: 2015

ISSN: 1755-375X

DOI: 10.1111/aos.12912