Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST
نویسندگان
چکیده
منابع مشابه
Erratum: A cross-sectional study to compare intraocular pressure measurement by sequential use of Goldman applanation tonometry, dynamic contour tonometry, ocular response analyzer, and Corvis ST
OBJECTIVE To study the correlation and effect of sequential measurement of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST. SETTING AND DESIGN Observational cross-sectional series from the comprehensive clinic of a tertiary eye care center seen during December 2012. METHODS One hundred and t...
متن کاملintraocular pressure measurements after penetrating keratoplasty using the ocular response analyzer versus goldmann applanation tonometer
purpose: to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and to evaluate the influence of anatomical and biomechanical properties of the grafts on iop measurements. methods: this cross-sectional study was conducted on 45 kerat...
متن کاملComparison of ICare, dynamic contour tonometer, and ocular response analyzer with Goldmann applanation tonometer in glaucoma
Purpose. To compare the intraocular pressure (IOP) readings taken by ICare, Pascal dynamic contour tonometer (DCT), and ocular response analyzer (ORA) with those taken by Goldmann applanation tonometer (GAT). We sought to evaluate the influence of central corneal thickness (CCT) on IOP measurements and to compare patients’ preferences for the four tonometers. Methods. In this prospective study,...
متن کاملThe Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma
It is important to compare the results of Corneal Visualization Scheimpflug Technology instrument (CST) measurements and Reichert Ocular Response Analyzer (ORA) parameters. The purpose of the study was to investigate the association between CST measurements and ORA parameters in ninety-five patients with primary open-angle glaucoma. Measurements of CST, ORA, axial length (AL), average corneal c...
متن کاملcomparison of intraocular pressure measurements by the ocular response analyzer and goldmann applanation tonometer after penetrating keratoplasty in keratoconic patients
purpose : to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and evaluate the influence of anatomical and biomechanical properties of the grafts on the iop measurements methods : in this cross-sectional study conducted on 45 kera...