During surgery for colon cancer, monitoring of the oxygen saturation hemoglobin in tissues under study makes it possible to assess degree blood supply anastomosis areas colon. Adequate this area is decisive terms consistency and can significantly reduce risk leakage anastomosis. In work, we propose a new approach assessing based on measuring both diffuse reflectance transmittance spectra wall tissues. The proposed method use two fiber-optic tools irradiation from sides—the intestinal lumen outside wall. are recorded external side. To determine saturation, algorithms, Taylor series expansion coefficient light attenuation by tissues, proposed. results clinical volunteers were obtained, allowing draw conclusion about applicability setting.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative colon mucosal oxygen saturation during aortic surgery.

BACKGROUND Colonic ischemia after aortic reconstruction is a devastating complication with high mortality rates. This study evaluates whether Colon Mucosal Oxygen Saturation (CMOS) correlates with colon ischemia during aortic surgery. MATERIALS AND METHODS Aortic reconstruction was performed in 25 patients, using a spectrophotometer probe that was inserted in each patient's rectum before the ...

متن کامل

the effect of e-64 on the developmental competence of sheep cocs during in vitro maturation

in the present study, the effect of e-64 at different concentrations (0.5, 1, 5 and 10 µm) added to (1) the ivm medium on oocyte nuclear maturation and developmental competence of ovine oocytes, and (2) to the ivc medium on embryonic development of ovine embryos were investigated.

Continuous monitoring of mixed venous oxygen saturation during aortic surgery.

The correlation between mixed venous oxygen saturation (SvO2) and hemodynamic measurements was studied in 13 patients undergoing descending thoracic aortic aneurysm resection (DTAAR). A significant correlation (p less than 0.05) was found between cardiac index (CI) and SvO2 after the induction of anesthesia and at the end of surgery. However, no significant correlation could be found between Sv...

متن کامل

Correlation between capillary oxygen saturation and small intestinal wall thickness in the equine colic patient

The surgical evaluation of haemorrhagic infarcted intestine and the decision for or against bowel resection require a lot of experience and are subjective. The aim of this prospective, clinical study was to examine the correlation between oxygen saturation and small intestinal wall (IW) thickness, using two objective methods. In 22 colicky horses, the blood flow, oxygen saturation and relative ...

متن کامل

Diagnostic Dilemma: Low Oxygen Saturation during Cardiac Surgery

We report a case of rheumatic heart disease with severe mitral stenosis having cyanosis and low oxygen saturation on pulse oximetry. The findings of clinical examination and low values on pulse oximetry were inconsistent with the findings of normal partial pressure of oxygen and oxygen saturation on arterial blood gas analysis, leading to diagnostic dilemma. In such clinical scenario, the anest...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Photonics

سال: 2021

ISSN: ['2304-6732']

DOI: https://doi.org/10.3390/photonics8100427