Intraoperative monitoring of visual function
نویسندگان
چکیده
منابع مشابه
Intraoperative monitoring of flash visual evoked potential under general anesthesia
In neurosurgical procedures that may cause visual impairment in the intraoperative period, the monitoring of flash visual evoked potential (VEP) is clinically used to evaluate visual function. Patients are unconscious during surgery under general anesthesia, making flash VEP monitoring useful as it can objectively evaluate visual function. The flash stimulus input to the retina is transmitted t...
متن کاملIntraoperative neurophysiologic monitoring.
A catalog record for this publication is available from the British Library Library of Congress Cataloging in Publication data Intraoperative neurophysiologic monitoring / Gloria M. Galloway. .. [et al.]. p. ; cm. Includes bibliographical references and index. Cambridge University Press has no responsibility for the persistence or accuracy of URLs for external or third-party internet websites r...
متن کاملinterpersonal function of language in subtitling
translation as a comunicative process is always said to be associated with various aspects of meaning loss or gain. subtitling as a mode of translating, due to special discoursal and textual conditions imposed upon it, is believed to be an obvious case of this loss or gain. presenting the spoken sound track of a film in writing and synchronizing the perception of this text by the viewers with...
15 صفحه اولA Comprehensive Review of Intraoperative Parathyroid Hormone Monitoring A Comprehensive Review of Intraoperative Parathyroid Hormone Monitoring
Intraoperative parathyroid hormone monitoring (IOPTH) has changed the surgical approach to primary hyperparathyroidism (PHPT). The traditional approach for the treatment of PHPT is a bilateral neck exploration (BNE), which entails the identification of all parathyroid glands and resection of the abnormal glands. However, with the advent of improved surgical adjuncts, including preoperative ultr...
متن کاملIntraoperative monitoring during vascular surgery.
The principal objectives of intraoperative monitoring are to improve perioperative outcome, facilitate surgery and reduce adverse events, using continuously collected data of cardiopulmonary,neurologic and metabolic function to guide pharmacologic and physiologic therapy. Although sophisticated and reliable apparatus may be used to collect these data they are useless, or even harmful, without p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Neurochirurgica
سال: 2011
ISSN: 0001-6268,0942-0940
DOI: 10.1007/s00701-011-1100-8