Introduction of a novel ultrahigh sensitivity collimator for brain SPECT imaging
نویسندگان
چکیده
منابع مشابه
Performance of a novel collimator for high-sensitivity brain SPECT.
We assessed improvements in performance in detection and estimation tasks due to a novel brain single photon computed tomography collimator. Data were acquired on the CeraSPECT scanner using both new and standard collimators. The new variable focusing collimator SensOgrade samples the projections unequally, with central regions more heavily represented, to compensate for attenuation of counts f...
متن کاملCollimator design for a multipinhole brain SPECT insert for MRI.
PURPOSE Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolu...
متن کاملCollimator design for a clinical brain SPECT/MRI insert
The Institute of Nuclear Medicine, University College London, London, UK This project’s goal is to design a SPECT insert for a clinical MRI system for simultaneous brain SPECT/MR imaging. We assume the stationary SPECT insert will consist of two rings of ∼5x5-cm SiPM-based detectors insensitive to magnetic fields, with 0.8-mm intrinsic resolution. The maximum diameter is 44.5 cm, the minimum di...
متن کاملNonuniform collimator sensitivity: improved precision for quantitative SPECT.
UNLABELLED Attenuation of photons degrades both the accuracy and the precision of SPECT images; attenuation correction algorithms correct the bias but cannot improve precision. Increased noise due to photon attenuation is most pronounced in regions deep in solid body sections, such as the brain and abdomen. We have quantified the degradation in performance in several estimation tasks that can b...
متن کاملSensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: Comparison of planar and SPECT imaging
Introduction: Although PET scanning using F-18[FDG] is considered the superior radiotracer for tumnor imaging, Gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. One of the strategies to improve the diagnostic accuracy of Gallium is to perform SPECT which is reported to be more sensitive compared to planar imaging. In this study we compa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2016
ISSN: 0094-2405
DOI: 10.1118/1.4958962