Inversion recovery TrueFISP: quantification of T(1), T(2), and spin density.

A novel procedure is proposed to extract T(1), T(2), and relative spin density from the signal time course sampled with a series of TrueFISP images after spin inversion. Generally, the recovery of the magnetization during continuous TrueFISP imaging can be described in good approximation by a three parameter monoexponential function S(t) = S(stst)(1-INV exp(-t/T(*) (1)). This apparent relaxatio...

متن کامل

3D Time-of-Flight MRA Using Inversion Recovery TrueFISP

A major drawback of 3D time-of-flight (TOF) sequences is progressive saturation of inflowing spins along the slab direction, and a sufficient long TR or shaped excitation pulses are required to compensate for this. Here we present a new TOF technique based on a combination of selective inversion and 3D acquisition with TrueFISP. The stationary tissue is partially suppressed by the inversion pul...

متن کامل

Rapid 3D Relaxation Time and Proton Density Quantification Using a Modified Radial IR TrueFisp Sequence

Introduction: A promising approach for the simultaneous quantification of proton density, T1 and T2 is the IR TrueFISP sequence proposed by Schmitt et al. [1]. This sequence consists of an inversion pulse followed by a series of TrueFISP acquisitions, observing a quasirelaxation towards the steady-state. However, this sequence requires a delay between individual segments in order to allow the m...

متن کامل

Phase-sensitive inversion recovery (PSIR) single-shot TrueFISP for assessment of myocardial infarction at 3 tesla.

PURPOSE The aim of the current study was to show if contrast-to-noise ratio (CNR) could be improved without loss of diagnostic accuracy if a phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence is used at 3.0 T instead of 1.5 T. MATERIAL AND METHODS Ten patients with myocardial infarction were examined on a 1.5 T magnetic resonance (MR) system (Avanto, Siemens Medical Syste...

متن کامل

Dual-relaxation, temporally-constrained, dynamic contrast-enhanced MRI using inversion recovery TrueFISP

Introduction: Inversion recovery (IR) TrueFISP imaging sequences have recently been used to acquire dynamic contrast enhanced (DCE) MRI data due to their short acquisition time, sensitivity to changes in tissue longitudinal relaxation times and superior signal-to-noise characteristics [1]. Use of an inversion recovery preparation offers the ability to quantify relaxation time changes at each dy...