Investigation on the inductive and resistive fault current limiting HTS power cable
نویسندگان
چکیده
منابع مشابه
Selection of Resistive and Inductive Superconductor Fault Current Limiters Location Considering System Transient Stability
Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...
متن کاملAn Optimal Design Approach for Resistive and Inductive Superconducting Fault Current Limiters via MCDM Techniques
The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension, resistance, and operating temperature can affect the limiting mode, quench time, and restore time. In this paper, following the simulation of...
متن کاملAn Investigation of the Current Distribution in an HTS Triaxial Power Cable and its Operational Impacts on a Power System
An investigation of the current distribution in a 3-phase triaxial superconducting cable was conducted to study the phase imbalance under steady-state operation and to assist in the construction of a transient model to study operational impacts in a power grid. The triaxial cable consisted of three superconducting concentric phases inside a copper shield, with each phase composed of multiple la...
متن کاملselection of resistive and inductive superconductor fault current limiters location considering system transient stability
superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...
متن کاملResistive power divider for magneto-inductive waveguides
Addressing the need for passive magneto-inductive components, a lumped-element symmetric power divider has been designed and realised for a magneto-inductive cable with the resonant frequency of 95 MHz and the passband between 73 and 174 MHz. In agreement with the theory, the measured coupling loss is 6 dB for most of the passband independent of the input port. Having proved useful for magneto-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Progress in Superconductivity and Cryogenics
سال: 2014
ISSN: 1229-3008
DOI: 10.9714/psac.2014.16.2.059