Ion-induced electron emission reduction via complex surface trapping
نویسندگان
چکیده
منابع مشابه
Exciton autoionization in ion-induced electron emission.
We report on measurements of electron emission spectra from surfaces of highly oriented pyrolytic graphite (HOPG) excited by 1-5 keV He+ and Li+ which, for He+, exhibit a previously unreported high-energy structure. Through a full quantum dynamic description that allows for the calculation of neutralization and electron-hole pair excitation, we show that these high-energy electrons can arise fr...
متن کاملIon-induced electron emission patterns in condensed matter
We will briefly present here a collaboration work that has recently started in the frame of the GSI Heavy Ion Radiotherapy project. The motivation of this work is to obtain valuable and systematic data of the ion-induced electron emission in condensed matter, especially emission patterns for slow electrons in terms of direction and energy and their dependencies on target density, projectile mas...
متن کاملModular cryostat for ion trapping with surface-electrode ion traps.
We present a simple cryostat purpose built for use with surface-electrode ion traps, designed around an affordable, large cooling power commercial pulse tube refrigerator. A modular vacuum enclosure with a single vacuum space facilitates interior access and enables rapid turnaround and flexibility for future modifications. Long rectangular windows provide nearly 360° of optical access in the pl...
متن کاملElectron Emission from Inconel under Ion Bombardment
Electron yields from clean and oxydized Inconel 625 surfaces have been measured for H', H:, Hef, 0' and Ar+ ions at normal incidence in the energy range 1.5-40 keV. These measurements have been made under ultrahigh vacuum and the samples were freed of surface contaminants by bombarding with high doses of either 20 keV H l or 30 keV Ar+ ions. Differences in yields of oxydized versus clean surfac...
متن کاملCryogenic ion trapping systems with surface-electrode traps.
We present two simple cryogenic rf ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 h. The ion traps are operated either in a liquid helium bath cryostat or in a low vibration closed cycle cryostat. The fast turn around time and availability of buffer gas cooling made the systems ideal for testing surface-electrode ion traps. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: AIP Advances
سال: 2019
ISSN: 2158-3226
DOI: 10.1063/1.5120519