Ion mobility spectrometer with orthogonal X-Ray source for increased sensitivity

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High sensitivity field asymmetric ion mobility spectrometer.

A high sensitivity field asymmetric ion mobility spectrometer (FAIMS) was designed, fabricated, and tested. The main components of the system are a 10.6 eV UV photoionization source, an ion filter driven by a high voltage/high frequency n-MOS inverter circuit, and a low noise ion detector. The ion filter electronics are capable to generate square waveforms with peak-to-peak voltages up to 1000 ...

متن کامل

Ion mobility spectrometer with radial collisional focusing.

An ion mobility spectrometer that has its mobility cell as a 20-segment quadrupole and functionally the q2 of a triple-quadrupole mass spectrometer has been assembled and tested. The combination of high cell pressure (maximum of 4 Torr of helium) and low axial field (20-160 V per 20.2 cm) results in negligible internal excitation of the ions despite applications of rf and axial fields. The pres...

متن کامل

The NEAR X-Ray/Gamma-Ray Spectrometer

he X-Ray/Gamma-Ray Spectrometer on the Near Earth Asteroid Rendezvous (NEAR) spacecraft will remotely sense X-ray and gamma-ray emissions from the surface of near-Earth asteroid 433 Eros and look for characteristic “signatures” in those emissions to determine its elemental composition. During the planned 10 months of orbits about Eros beginning in early 1999, data returned from the instrument w...

متن کامل

Ion dynamics in a trapped ion mobility spectrometer.

In the present paper, theoretical simulations and experimental observations are used to describe the ion dynamics in a trapped ion mobility spectrometer. In particular, the ion motion, ion transmission and mobility separation are discussed as a function of the bath gas velocity, radial confinement, analysis time and speed. Mobility analysis and calibration procedure are reported for the case of...

متن کامل

X-ray Absorption Spectroscopy Using X–ray Fluorescence Spectrometer

Strong characteristic Kα X-ray lines are accompanied by weak lines due to the radiative Auger effect (RAE) [1, 2]. The characteristic Kα fluorescent X-rays (K-L2,3 lines) are emitted by the 2p→1s electric dipole transition after one of the 1s electron photoionization, Though the probability is less than 0.01, one of the 2p electrons is excited into an unoccupied discrete or continuum level simu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Talanta

سال: 2018

ISSN: 0039-9140

DOI: 10.1016/j.talanta.2018.04.035