Ionization chamber correction factors for MR-linacs

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absorbed dose dependence of the correction factors for ionization chamber cable irradiation effects.

A simple method was developed, for possible use by hospital physicists, to evaluate the irradiation effects on cables and connectors during large-radiation-field dosimetry with ionization chambers and to determine correction factors for the used system or geometry. This method was based on the absorbed dose dependence of the correction factor.

متن کامل

A New Trajectory Correction Technique for Linacs’

In this paper, we describe a new trajectory correction technique for high energy linear accelerators. Current correction techniques force the beam trajectory to follow misalignments of the Beam Position Monitors (BPMs). Since the particle bunch has a finite energy spread and particles with different energies are deflected differently, this causes “chromatic” dilution of the transveise beam emit...

متن کامل

An EGSnrc investigation of correction factors for ion chamber dosimetry

Radiation dosimetry is used to quantify the dose delivered during radiation therapy by using ionization chambers with several correction factors. Knowledge of these factors is needed at well below the 1% level in order to maintain the overall uncertainty on the reference dosimetry near 1-2%. The small magnitude of the corrections renders measurements very difficult. Monte Carlo calculations are...

متن کامل

Perturbation correction factors for the NACP-02 plane-parallel ionization chamber in water in high-energy electron beams.

Recent dosimetry protocols for clinical high-energy electron beams recommend measurements of absorbed dose-to-water with a plane-parallel or cylindrical ionization chamber. For well-guarded plane-parallel ionization chambers, the ionization chamber perturbation factor in water, p(Q), has a recommended value of unity in all protocols. This assumption was investigated in detail in this study for ...

متن کامل

Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physics in Medicine & Biology

سال: 2018

ISSN: 1361-6560

DOI: 10.1088/1361-6560/aac4f2