Isotope Ratio Mass Spectrometry.
Isotope Ratio Mass Spectrometry (IRMS) is a specialized technique used to provide information about the geographic, chemical, and biological origins of substances. The ability to determine the source of an organic substance stems from the relative isotopic abundances of the elements which comprise the material. Because the isotope ratios of elements such as carbon, hydrogen, oxygen, sulfur, and...
متن کاملContinuous-flow isotope ratio mass spectrometry method for carbon and hydrogen isotope measurements on atmospheric methane
We describe a continuous-flow isotope ratio mass spectrometry (CF-IRMS) technique for high-precision δD and δ13C measurements of atmospheric methane on 40 mL air samples. CH4 is separated from other air components by utilizing purely physical processes based on temperature, time and mechanical valve switching. Chemical agents are avoided. Trace amounts of interfering compounds can be separated ...
متن کاملIntroduction to Radiocarbon Determination by the Accelerator Mass Spectrometry Method
There are three principal isotopes of carbon which occur naturally C, C (both stable) and C (unstable or radioactive). These isotopes are present in the following amounts C 98.89%, C 1.11%, and C 0.00000000010%. Thus, one carbon-14 atom exists in nature for every 1,000,000,000,000 or (1 in a trillion) carbon-12 atoms in living material. The radiocarbon method is based on the rate of decay of th...
متن کاملIsotope-Ratio-Monitoring Gas Chromatography-Mass Spectrometry
RECEIVED for review February 21, 1978. Accepted June 19, 1978. NMR spectra since two distinct peaks (6 -3.38, 3.78 ppm) caused by these protons are observed in CDCA vs. only one peak (6 -3.45 ppm) caused by the same protons in UDCA. T h e fingerprint region of the spectrum (6 1-2.5 ppm) and the relative position of the CIS methyl peak with respect to tha t of the doublet caused by the Cpl methy...
متن کاملTechnetium Measurements by Accelerator Mass Spectrometry at LLNL
Technetium-99 is a long-lived, high-abundance fission product which has been widely distributed in the environment through atmospheric testing, the nuclear fuel cycle, and nuclear medicine. It has a high potential for migration in the environment as the pertechnetate anion. At the Center for Accelerator Mass Spectrometry, methods are being developed for the detection of this radionuclide by acc...