Cardiac dysrhythmias after transcatheter closure of ASD with Amplatzer device.
Transcatheter closure of atrial septal defect (ASD) has been used as an alternative to open heart surgery. Although transcatheter closure of ASD with the Amplatzer septal occluder is a safe and feasible method in pediatric patients, there is little published data on arrhythmia analysis following transcatheter device closure of secundum ASD. We evaluated cardiac dysrhythmias with 24-hour ambulat...
متن کاملAnterior Minithoracotomy: a Safe Approach for Surgical ASD Closure & ASD Device Retrieval
OBJECTIVE Midline sternotomy is the preferred approach for device migration following transcatheter device closure of ostium secundum atrial septal defect. Results of patients operated for device migration were retrospectively reviewed after transcatheter closure of atrial septal defect. METHODS Among the 643 patients who underwent atrial septal defect with closure device, 15 (2.3%) patients ...
متن کاملdevice-induced perforation of right atrium following interventional closure of atrial septal defect (asd)
this is a case presentation of a 26-year-old woman with a moderate-sized atrial septal secundum defect (17mm) who underwent catheterism, during which an amplatzer septal occluder number 26 was inserted successfully. on the second postoperative day, she deteriorated and a clinical examination showed a typical tamponade. after a percutaneous aspiration of the pericardial cavity and transient impr...
متن کاملExperimental ASD closure using autologous cell-seeded interventional closure devices.
OBJECTIVE Atrial septal defect (ASD) occluders are permanent implants in paediatric cardiology which serve as mechanical shields until complete overgrowth and incorporation of the occluding device by autologous tissue has occurred. Thereafter, the foreign body material making up the device is dispensable and bears potential long-term adverse effects. Rapid, firm and complete incorporation into ...
متن کاملTranscatheter Device Closure of Secundum Atrial Septal Defect (asd) in Young Children
Objective: To analyze the safety and efficacy of device closure of secundum atrial septal defect in children ≤ 5 years of age. Study Design: Quasi-experimental study. Place and Duration of Study: The study was conducted at Armed Forces Institute of Cardiology / National Institute of Heart Diseases Rawalpindi, Pakistan from Dec 2010 Dec 2012. Patients and Method: Forty eight patients ≤ 5 years o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Pediatric Cardiology
سال: 2011
ISSN: 0974-2069
DOI: 10.4103/0974-2069.84658