Late Cardiac Rupture after Amplatzer Septal Occluder Implantation
نویسندگان
چکیده
منابع مشابه
Incomplete endothelialization and late dislocation after implantation of an Amplatzer septal occluder device.
A 64-year-old woman with a history of a large-sized secundum atrial septal defect (ASD) underwent successful percutaneous closure with a 34-mm Amplatzer septal occluder (ASO) without apparent complications on April 25, 2002. Transthoracic echocardiography immediately following the closing procedure revealed that her ASO was well wedged, with no residual shunt or murmurs (Figure 1). At the third...
متن کاملLate Bacterial Endocarditis and Abscess Formation After Implantation of an Amplatzer Septal Occluder Device.
A 37-year-old man was referred to our emergency department after 4 days of a spiking fever of up to 40°C, myalgia, and new development of multiple, small, nontender erythematous macular lesions on his palms and soles compatible with Janeway lesions (Figure 1). He had a history of a large secundum atrial septal defect for which he underwent transcatheter closure with a 24-mm Amplatzer septal occ...
متن کاملCardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder.
OBJECTIVES Amplatzer septal occluder (ASO)-associated cardiac perforation (CP) at our institution prompted this retrospective review. BACKGROUND Cardiac perforation is a rare complication after transcatheter atrial septal defect (ASD) closure. METHODS To identify CP after transcatheter ASD closure with ASO, cardiac events (CE) describing definite CP, hemopericardium, pericardial effusion, c...
متن کاملImages in Cardiovascular Medicine Incomplete Endothelialization and Late Dislocation After Implantation of an Amplatzer Septal Occluder Device
A 64-year-old woman with a history of a large-sized secundum atrial septal defect (ASD) underwent successful percutaneous closure with a 34-mm Amplatzer septal occluder (ASO) without apparent complications on April 25, 2002. Transthoracic echocardiography immediately following the closing procedure revealed that her ASO was well wedged, with no residual shunt or murmurs (Figure 1). At the third...
متن کاملTranscatheter retrieval of embolized AMPLATZER Septal Occluder.
In selected patients, transcatheter closure of atrial septal defects with the AMPLATZER Septal Occluder has yielded excellent results. However, there is a slight risk of device embolization after deployment. We report the case of a 26-year-old woman in whom an embolized AMPLATZER device was retrieved percutaneously from the right pulmonary artery. We also discuss important technical principles ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Texas Heart Institute Journal
سال: 2016
ISSN: 0730-2347,1526-6702
DOI: 10.14503/thij-15-5635