Lateral Current Reduction by Voltage Drop Compensator for Multiple Autonomously Controlled UPS Connected in Parallel
نویسندگان
چکیده
منابع مشابه
Mitigation of Inrush Current of Transformer using Voltage Sag Compensator
In the power system voltage sag become the important issue for industries. According to the survey 92% of the interruptions at industrial installations are voltage sag related. In various companies voltage sag may affect many manufactures and introduce sufficient losses in the power system. The voltage sag compensator, based on a transformer coupled series connected voltage source inverter, is ...
متن کاملControl of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
متن کاملInfluence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملA New Approach for Low Voltage CMOS based on Current-controlled Conveyors
Abstract In his paper a new current-controlled conveyor (CCCII) in CMOS technology is presented. It features, low supply voltage (±0.7), low power consumption, low circuit complexity, rail to rail operation and wide range parasitic resistance ( ). The circuit has been successfully employed in a multifunction biquad filter. Simulation results by HSPICE show high performance of the circuit and c...
متن کاملOptimized Fuzzy Controller Design in Unbalanced Voltage Drop Mode for Dynamic Voltage Restorer
The loss of balanced voltages involves a voltage drop due to symmetric three-phase errors, or the initiation of high-power three-phase loads or symmetric three-phase switches. While these events in an unbalanced way lead to asymmetric voltage drops. Voltage drops can cause asymmetric load on the power grid, the occurrence of volatility, and even network power outage. One of the most common ways...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Industry Applications
سال: 2005
ISSN: 0913-6339,1348-8163
DOI: 10.1541/ieejias.125.934