LATERAL LOADING TEST ON STEEL FRAMES WITH 3-SPANNED CONTINUOUS COMPOSITE BEAMS
نویسندگان
چکیده
منابع مشابه
OPTIMAL PERFORMANCE-BASED SEISMIC DESIGN OF COMPOSITE BUILDING FRAMES WITH RC COLUMNS AND STEEL BEAMS
Composite RCS building frames integrate reinforced concrete columns with structural steel beams to provide an efficient solution for the design and construction of earthquake-resisting structures. In this paper, an optimization framework is developed for performance-based seismic design of planar RCS moment resisting frames. The objective functions are defined as minimizing the construction cos...
متن کاملFinite Element Instability Analysis of the Steel Joist of Continuous Composite Beams with Flexible Shear Connectors
Composite steel/concrete beams may buckle in hogging bending regions. As the top flange of I-beam in that arrangement is restricted from any translational deformation and twist, the web will distort during buckling presenting a phenomenon often described as restricted distortional buckling. There are limited studies available in the literature of restricted distortional buckling of composite st...
متن کاملERFORMANCE-BASED SEISMIC DESIGN OPTIMIZATION OF COMPOSITE MOMENT RESISTING FRAMES WITH CONCERETFILLED STEEL COLUMNS AND STEEL BEAMS
In this paper, an optimization framework is developed for performance-based seismic design of composite moment frames consisting of concrete filled steel box columns and I-shaped steel beams. Material cost of the structure and seismic damage under severe earthquake ground motions are minimized as objective functions. Two design examples are presented to demonstrate the applicability and efficie...
متن کاملInfluence of Shear Connection Distributions on the Behaviour of Continuous Steel-concrete Composite Beams
For this purpose a finite element model specifically developed for the nonlinear analysis of steel-concrete composite beams is adopted. This finite element model includes material nonlinearity of slab concrete, reinforcement steel, beam steel as well as slabbeam nonlinear partial interaction due to the deformable shear connection. The inclusion of the partial interaction in the composite beam m...
متن کاملan investigation on steel knee braced frames for lateral loads
hysteretic dampers as the most practical passive control methods have improved the seismic performance of steel structures through energy dissipation induced by large inelastic deformations. among them in this paper, kbf (knee braced frames), a special form of braced frames having a diagonal brace connected to a knee element instead of beam-column joint, is investigated. in such systems, the kn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 1996
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.61.121_4