Lateral Mixing in Channels due to Secondary Currents
نویسندگان
چکیده
منابع مشابه
Mixing in gravity currents
We study entrainment in lock-release gravity currents using highly spatially resolved optical transmission experiments and quantitative analysis of the available potential energy of the flow. The principal results provide a resolution to the debate regarding the mechanism and degree of mixing in the head of a gravity current during the slumping phase. The nature of the complex internal mixing s...
متن کاملan investigation of the influence of longitudinal channel slope on secondary currents in compound channels using 2 d momentum model
secondary flow investigation could be regarded as an important issue in open channel flow, in spite of its lower quantity compared to the base flow in the water course. it should be given special consideration because of the influence on some hydraulic factors in open channel, specifically in compound channels. in compound channels' due to the difference in the flow velocity of the main ch...
متن کاملNumerical and Empirical Investigation of Flow Separation Phenomenon around Semi-buried Pipelines due to Steady Currents
In this paper, in order to understand the flow-pipe interaction more clearly, the variations on flow pattern around semi-buried pipelines due to steady current have physically and numerically been investigated. In physical modeling section, the experiments have been carried out in a flume with 10 meter length, 0.3 meter width and 0.5 meter depth using a P.V.C pipe with 6.35 cm in diameter (for ...
متن کاملSecondary glaucoma due to anterior chamber lipoma and uveitis in a Pekingese dog
The present study introduces a rare case with secondary glaucoma due to anterior chamber lipoma and uveitis in a Pekingese dog in Iran. A four-year-old castrated male Pekingese dog was referred to the private clinic with impaired vision of the left eye, pain, rubbing the left eye onto carpet, presence of a milkycoloured mass into the anterior chamber, and loss of appetite. The clinical examinat...
متن کاملAssessment of secondary neutron dose due to dental restorations in head and neck radiation therapy
Introduction: One of scientific concern is increasing of unwanted neutron dose to the patient, in head and neck radiation therapy due to the presence of some isotopes in dental restorations and head of medical linac. The aim of this study is to measure the equivalent dose of thermal and fast neutron due to head of Siemens Primus Linac and a healthy tooth, Amalgam, Ni-Cr alloy a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Hydrology Research
سال: 1986
ISSN: 0029-1277,2224-7955
DOI: 10.2166/nh.1986.0030