Lead-sensitive membrane electrode based on chelating ion exchanger

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Cu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...

متن کامل

Sn (II) Ion- Selective Membrane Electrode based on Dibenzo-18-Crown-6

We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...

متن کامل

selective membrane electrode for bromide ion based on aza pyrilium ion derivative as a new ionophore.

a highly selective electrode for bromide ion based on aza pyrilium derivative as an excellentionophore is described.the sensor exhibits a good linear response with a slope of ( 60±1 ) mv per decadeover the concentration range of ( 1×10-3 – 9×10-6 m ) , and a detection limit of ( 3×10-6 m ) of bromideions .the electrode response is independent of ph in the range of(4.0 –9.5).selectivity coeffici...

متن کامل

Histidine as the Functional Group for a Chelating Ion Exchanger

In the chelating ion exchanger synthesized, the amino group of histidine is attached chemically via the azide method to the carboxyl group of Amberlite IRC-50. A flow system based on a spectrophotometric detector, with 4-( 2-pyridylazo)resorcinol as reagent, is described for fast assays of eluted cations. The pH dependence of the metal extraction is reported for Ag(I), Au(III), Cu(II), Fe(III),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Arabian Journal of Chemistry

سال: 2010

ISSN: 1878-5352

DOI: 10.1016/j.arabjc.2010.02.004