Leak Detection of Water Supply Networks Using Error-Domain Model Falsification
نویسندگان
چکیده
منابع مشابه
Model falsification diagnosis and sensor placement for leak detection in pressurized pipe networks
Pressurized pipe networks used for fresh-water distribution can take advantage of recent advances in sensing technologies and data-interpretation to evaluate their performance. In this paper, a leak-detection and a sensor placement methodology are proposed based on leak-scenario falsification. The approach includes modeling and measurement uncertainties during the leak detection process. The pe...
متن کاملHead-Driven Simulation of Water Supply Networks
Up to now most of the existing water supply network analyses have been based on demand-driven simulation models. These models assume that nodal outflows are fixed and are always available. However, this method of simulation neglects the pressure-dependent nature of demand that is characterized by changes in actual nodal outflows particularly during critical events like major mechanical or hydra...
متن کاملOptimization model of water supply networks design
The paper approaches the optimization of water distribution networks supplied from one or more node sources, according to demand variation. Traditionally, in pipe optimization, the objective function is always focused on the cost criteria of network components. In this study an improved linear model is developed, which has the advantage of using not only cost criteria, but also energy consumpti...
متن کاملLEAK DETECTION IN WATER DISTRIBUTION SYSTEM USING NON-LINEAR KALMAN FILTER
Leakage detection in water distribution systems play an important role in storage and management of water resources. Therefore, to reduce water loss in these systems, a method should be introduced that reacts rapidly to such events and determines their occurrence time and location with the least possible error. In this study, in order to determine position and amount of leakage in distribution ...
متن کاملEfficient model-based leak detection in boiler steam-water systems
A model-based least-squares algorithm with a time-varying forgetting factor is developed for leak detection in boiler steam-water systems. The algorithm has been tested using real industrial data from Syncrude Canada, and has proven to be effective in detection of boiler tube or steam leaks; proper implementation of the algorithm would lead to early leak warning, which is important in maintaini...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Computing in Civil Engineering
سال: 2018
ISSN: 0887-3801,1943-5487
DOI: 10.1061/(asce)cp.1943-5487.0000729