Left ventricular function depends on previous beat ejection but not previous beat pressure load.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left ventricular function depends on previous beat ejection but not previous beat pressure load.

Previous beat contraction history, in which the performance of the left ventricle on any one beat is influenced by the mechanical events of the previous beat, may be important in the beat-to-beat regulation of left ventricular performance in the intact cardiovascular system. Prior studies of this phenomenon have established that mechanical events of the previous beat influence the function of t...

متن کامل

Previous Beat Ejection but Not Previous Beat Pressure Load

Previous beat contraction history, in which the performance of the left ventricle on any one beat is influenced by the mechanical events of the previous beat, may be important in the beat-to-beat regulation of left ventricular performance in the intact cardiovascular system. Prior studies of this phenomenon have established that mechanical events of the previous beat influence the function of t...

متن کامل

Beat-to-beat Left Ventricular Performance

The feasibility, accuracy and reproducibility of continuous beat-to-beat evaluation of left ventricular performance with a computerized nonimaging scintillation probe was assessed in 71 patients. This portable instrument has enough sensitivity to generate a real-time relative left ventricular volume curve using the labeled equilibrium blood pool without electrocardiographic gating. The probe wa...

متن کامل

Left ventricular beat to beat performance in atrial fibrillation: dependence on contractility, preload, and afterload.

OBJECTIVE To assess independent determinants of beat to beat variation in left ventricular performance during atrial fibrillation. DESIGN Prospective study. SETTING University hospital. PATIENTS Seven patients with chronic non-valvar atrial fibrillation. INTERVENTIONS Invasive and non-invasive haemodynamic variables were assessed using a non-imaging computerised nuclear probe, a balloon...

متن کامل

Effect of midazolam on transfer function between beat-to-beat arterial pressure and inter-beat interval length.

Arterial pressure (AP) and inter-beat interval (IBI) length are under autonomic nervous system control. The control mechanisms can be investigated by transfer function analysis. It is not known if this type of analysis may be helpful in monitoring depth of sedation. In an open-label, uncontrolled investigation, the effect of midazolam on the transfer function between AP and IBI, and on spectral...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Circulation Research

سال: 1991

ISSN: 0009-7330,1524-4571

DOI: 10.1161/01.res.69.4.1051