Light particle spectroscopy using CR-39 detectors: An experimental and simulation study

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alpha-particle radiobiological experiments using thin CR-39 detectors.

The present paper studied the feasibility of applying comet assay to evaluate the DNA damage in individual HeLa cervix cancer cells after alpha-particle irradiation. We prepared thin CR-39 detectors (<20 microm) as cell-culture substrates, with UV irradiation to shorten the track formation time. After irradiation of the HeLa cells by alpha particles, the tracks on the underside of the CR-39 det...

متن کامل

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector.

There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3...

متن کامل

Simple preparation of thin CR-39 detectors for alpha-particle radiobiological experiments

Alpha-particle radiobiological experiments involve irradiating cells with alpha particles and require accurate positions where the alpha particles hit the cells. In the present work, we prepared thin CR-39 detectors from commercially available CR-39 SSNTDs with a thickness of 100 lm by etching them in 1 N NaOH/ethanol at 40 C to below 20 lm. The desired final thickness was achieved within 8 h. ...

متن کامل

experimental and monte carlo studies on the response of cr-39 detectors to am-be neutron spectrum

background: the poly-allyl diglycol carbonate (padc) detector is of particular interest for development of a fast neutron dosimeter. fast neutrons interact with the constituents of the cr-39 detector and produce h, c and o recoils, as well as (n, α) reaction. these neutron- induced charged particles contribute towards the response of cr-39 detectors. material and methods: electrochemical etchin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms

سال: 2019

ISSN: 0168-583X

DOI: 10.1016/j.nimb.2019.04.012