Linear Quadratic Gaussian-Based Closed-Loop Control of Type 1 Diabetes

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Linear quadratic gaussian-based closed-loop control of type 1 diabetes.

BACKGROUND We investigated the applicability of linear quadratic Gaussian (LQG) methodology to the subcutaneous blood glucose regulation problem. We designed an LQG-based feedback control algorithm using linearization of a previously published metabolic model of type 1 diabetes. A key feature of the controller is a Kalman filter used to estimate metabolic states of the patient based on continuo...

متن کامل

Closed-loop control for pediatric Type 1 diabetes mellitus

Closed-loop clinical trials have resulted in significant advances with continuous glucose monitoring and control systems modulating insulin delivery. Those trials were performed in closely supervised clinical research settings; while adults with Type 1 diabetes were initially targeted, studies in children with Type 1 diabetes have followed in both clinical research units and pediatric diabetes ...

متن کامل

Linear-Quadratic Fractional Gaussian Control

A control problem for a linear stochastic system with an arbitrary fractional Brownian motion and a cost functional that is quadratic in the system state and the control is solved. An optimal control is given explicitly as the sum of a prediction of the future fractional Brownian motion and the well known linear feedback control for the associated deterministic linear-quadratic control problem....

متن کامل

A Closed Loop Control of Quadratic Boost Converter Using PID Controller

This paper presents an implementation of open loop and closed loop control of Quadratic boost converter using PID controller.  Quadratic boost converter consists of boost converter and fly back converter driven by a single switch. Quadratic boost converter QBC is designed especially for regulating the DC interface between various micro sources and dc-ac inverter to electricity grid. Quadratic b...

متن کامل

Closed-loop insulin delivery for treatment of type 1 diabetes

Type 1 diabetes is one of the most common endocrine problems in childhood and adolescence, and remains a serious chronic disorder with increased morbidity and mortality, and reduced quality of life. Technological innovations positively affect the management of type 1 diabetes. Closed-loop insulin delivery (artificial pancreas) is a recent medical innovation, aiming to reduce the risk of hypogly...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Diabetes Science and Technology

سال: 2007

ISSN: 1932-2968,1932-2968

DOI: 10.1177/193229680700100606