Liquid chromatography–flame ionisation detection using a nebuliser/spray chamber interface. Part 1. Design and testing
نویسندگان
چکیده
منابع مشابه
Formation interface detection using Gamma Ray log: A novel approach
There are two methods for identifying formation interface in oil wells: core analysis, which is a precise approach but costly and time consuming, and well logs analysis, which petrophysists perform, which is subjective and not completely reliable. In this paper, a novel coupled method was proposed to detect the formation interfaces using GR logs. Second approximation level (a2) of GR log gained...
متن کاملTesting of CsI Photocathodes Efficiencies in a Liquid Xenon Chamber
A summary of the Dark Matter problem and a more detailed overview of the WIMP/neutralino direct detection are introduced. More specifically the XENON – a next generation direct detection detector of WIMPs – is described. A detailed description is given on the techniques used in the current experiment to produce CsI photocathodes. Furthermore the tests done to check the performance of the CsI ph...
متن کاملUser Interface Design and Usability Testing of a Podcast Interface
...........................................................................................................................................I TIIVISTELMÄ..................................................................................................................................... II ACKNOWLEDGEMENTS...............................................................................................
متن کاملDesign, Development and Testing of a Semi Cylindrical Capacitive Array Type Liquid Interface Level Sensor
In this study, a semi cylindrical capacitive array type liquid interface level measuring sensor is described. The sensor consists of a continuous large semi cylindrical thin metallic plate acting as a common plate of the capacitor and an array of small semi cylindrical thin metallic plates, separated by very small gap distance. All plates are mounted along the outer wall of a cylindrical non co...
متن کاملA fully automated liquid–liquid extraction system utilizing interface detection
The development of the Abbott Liquid-Liquid Extraction Station was a result of the need for an automated system to perform aqueous extraction on large sets of newly synthesized organic compounds used for drug discovery. The system utilizes a cylindrical laboratory robot to shuttle sample vials between two loading racks, two identical extraction stations, and a centrifuge. Extraction is performe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Chromatography A
سال: 2012
ISSN: 0021-9673
DOI: 10.1016/j.chroma.2012.02.033