Liquid-liquid phase separation causes high turbidity and pressure during low pH elution process in Protein A chromatography

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-pressure liquid chromatography: separation

The high-pressure liquid chromatographic separation of ail of the known metabolites of vitamin D2 and vitamin D3 found in biological fluids has been achieved. This technique has been successfully applied to the analysis of vitamin D mixtures, purification of vitamin D metabolites, and identification of radioactive peaks. Some theoretical bases for the observed resolutions are suggested. Supplem...

متن کامل

High speed gradient elution reversed-phase liquid chromatography.

A major disadvantage of gradient elution in terms of speed results from the need to adequately re-equilibrate the column. This work distinguishes two states of re-equilibration: (1) run-to-run repeatability and (2) full equilibration. We find that excellent repeatability (+/-0.002 min in retention time) is achieved with at most 2 column volumes of re-equilibration whereas full equilibration can...

متن کامل

High-Pressure Liquid Chromatography

An isocratic reversed-phase high-pressure liquid chromatographic method for the determination of six components of the teicoplanin complex in biological fluid was developed. By using fluorescence detection after precolumn derivatization with fluorescamine, the assay is specific and highly sensitive, with reproducibility studies yielding coefficients of variation ranging from 1.5 to 8.5% (at 5 t...

متن کامل

High-performance Liquid Chromatography Separation

A h igh-per formance l i q u i d chromatography (HPLC) method has been deve loped f o r t h e s e p a r a t i o n of o l e f i n , s a t u r a t e , and a r o m a t i c hydrocarbons found i n h i g h b o i l i n g d i s t i l l a t e s and r e s i d u e s of s h a l e o i l and i n whole s h a l e o i l s . The dual-column chromatographic system uses s i l i c a g e l i n one column and s i l i...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Chromatography A

سال: 2017

ISSN: 0021-9673

DOI: 10.1016/j.chroma.2017.01.067