Lithium corrosion/mass transfer test facility
نویسندگان
چکیده
منابع مشابه
Deuteron beam interaction with lithium jet in a neutron source test facility I
Testing and evaluating candidate fusion reactor materials in a high-flux, high-energy neutron environment are critical to the success and economic feasibility of a fusion device. The current understanding of materials behavior in fission-like environments and existing fusion facilities is insufficient to ensure the necessary performance of future fusion reactor components. An accelerator-based ...
متن کامل1985 NF Test Facility
Near-field ranges operate by measuring the electromagnetic field near the antenna and then mathematically transforming the data to any arbitrary location. Near-field operations are a form of microwave holography. The wave front measurements are normally made on a planar, spherical or cylindrical surface. This paper discusses primarily the planar configurations as used in the measurement of larg...
متن کاملBuilding Integrated Photovoltaic Test Facility
The widespread use of building integrated photovoltaics appears likely as a result of the continuing decline in photovoltaic manufacturing costs, the relative ease in which photovoltaics can be incorporated within the building envelope, and the fact that buildings account for over 40 percent of the U.S. energy consumption. However, designers, architects, installers, and consumers need more info...
متن کاملThe JLC Accelerator Test Facility
highest-priority project for the future. Research and development toward the design of such a machine has occurred at KEK for more than a decade. Two major areas of current accelerator R&D at KEK include the technologies needed to generate high-quality beams in an injector complex and high-power microwave technology required for the main linear accelerators. Because its particle bunches encount...
متن کاملTheoretical Analysis of Effective Thermal Conductivity for the Chinese HTR-PM Heat Transfer Test Facility
The Chinese high temperature gas-cooled reactor pebble bed module (HTR-PM) demonstration project has attracted increasing attention. In order to support the project, a large-scale heat transfer test facility has been constructed for pebble bed effective thermal conductivity measurement over the whole temperature range (0~1600 ◦C). Based on different heat transfer mechanisms in the randomly pack...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Fusion Engineering and Design
سال: 1989
ISSN: 0920-3796
DOI: 10.1016/s0920-3796(89)80054-7