Live Processing of SF6 Insulated Gas Equipment in High Humidity Environment
نویسندگان
چکیده
منابع مشابه
Application of CNTs Gas Sensor in Online Monitoring of SF6 Insulated Equipment
The detection and analysis of SF6 decomposition components are of great significance in online condition assessment and fault diagnosis of GIS. Considering the shortcomings of general detection methods, carbon nanotubes (CNTs) gas sensor was studied to detect the SF6 decomposition components because of its advantages in large surface activity and abundant pore structure, et al. The large surfac...
متن کاملApplication of Graphene Gas Sensors in Online Monitoring of SF6 Insulated Equipment
Graphene is an allotrope of carbon apart from graphite, diamond, fullerene and carbon nanotubes. Because graphene has unique mechanical, structural, thermal and electrochemical properties and can present the stability characteristics of these features, it becomes two-dimensional (2-d) materials which can alter three-dimensional (3-d) carbon nanotubes composite materials and has important resear...
متن کاملApplication of TiO2 Nanotubes Gas Sensors in Online Monitoring of SF6 Insulated Equipment
Titanium dioxide nanotube arrays (TNTAs) are a typical three-dimensional nanomaterial. TNTA has rich chemical and physical properties and low manufacturing costs. Thus, TNTA has broad application prospects. In recent years, research has shown that because of its large specific surface area and nanosize effect, the TNTAs have an enormous potential for development compared with other nanostructur...
متن کاملPreparation and Application of TiO2 Nanotube Array Gas Sensor for SF6-Insulated Equipment Detection: a Review
Since Zwilling and co-workers first introduced the electrochemical anodization method to prepare TiO2 nanotubes in 1999, it has attracted a lot of researches due to its outstanding gas response and selectivity, making it widely used in gas detection field. This review presents an introduction to the sensor applications of TiO2 nanotube arrays (TNTAs) in sulfur hexafluoride (SF6)-insulated equip...
متن کاملStudy on the Characteristic Decomposition Components of DC SF6-Insulated Equipment under Positive DC Partial Discharge
Pulses with different amplitudes occur when an inner partial discharge fault exists in SF6-gas-insulated DC high-voltage electrical equipment. SF6 decomposes following complex physical and chemical processes. Discussing and quantifying the mathematical relationship of pulse discharge quantities to SF6 decomposition component characteristics is helpful to evaluate and predict the insulation faul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IOP Conference Series: Earth and Environmental Science
سال: 2018
ISSN: 1755-1315
DOI: 10.1088/1755-1315/199/4/042035