Local specific absorption rate control for parallel transmission by virtual observation points
نویسندگان
چکیده
منابع مشابه
Specific absorption rate monitor for in-vivo parallel transmission at 7 Tesla
When using a transmit array at high field, it is well established that high local specific absorption rate (SAR) values can occur [1]. In order to guarantee patient safety without harsh limitations to in-vivo transmit-SENSE [2] applications, subtle SAR monitoring is therefore necessary. In the recent past, a comprehensive solution involving pre-calculated B1-field-maps and local pickup-coils wa...
متن کاملSpecific absorption rate studies of the parallel transmission of inner-volume excitations at 7T.
PURPOSE To investigate the behavior of whole-head and local specific absorption rate (SAR) as a function of trajectory acceleration factor and target excitation pattern due to the parallel transmission (pTX) of spatially tailored excitations at 7T. MATERIALS AND METHODS Finite-difference time domain (FDTD) simulations in a multitissue head model were used to obtain B(1) (+) and electric field...
متن کاملEvaluation of maximum local SAR for parallel transmission (pTx) pulses based on pre-calculated field data using a selected subset of "Virtual Observation Points"
M. Gebhardt, D. Diehl, E. Adalsteinsson, L. L. Wald, and G. Eichfelder Siemens Healthcare, Erlangen, Germany, Siemens Corporate Technology, Erlangen, Germany, Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States, Martinos Center for Biomedical Imaging, Harvard University, Charlestown, MA, United States, Applied Mathematics II, Universi...
متن کاملControl Points for Adaptive Parallel Performance Tuning
This paper describes a new parallel program tuning framework, with a new approach for tuning. The application exposes tuning parameters while an adaptive runtime system tunes the values of the parameters as the program executes. The parameters are allowed to vary throughout the duration of a run of a program. This provides two benefits over using a static set of parameters for each program run....
متن کاملPulse Design Methods for Reduction of Specific Absorption Rate in Parallel RF Excitation
A. C. Zelinski, K. Setsompop, V. Alagappan, B. A. Gagoski, L. M. Angelone, G. Bonmassar, U. Fontius, F. Schmitt, E. Adalsteinsson, and L. L. Wald Department of Electrical Engineering and Computer Science, MIT, Cambridge, MA, United States, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA, United States, Siemens Medical Solutio...