Long Radial Sheath for Angiography of Femoral Artery Large Sheath Access Site with Vascular Closure Devices

نویسندگان

چکیده

Radial access combined with hemodynamic support has the limitation of not allowing adequate angiography or delivery peripheral balloons for managing femoral site after removal large sheath. We present a case series use novel long 6 French guiding sheath via left radial artery ventricular assist device vascular closure devices.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radial Artery Perforation Management with Internal Tamponade using a Long Vascular Sheath

Radial artery access has rare but significant vascular complications that can occur even in high volume centers. We present a case of a 60-year-old man with perforation of a high takeoff radial artery due to catheter manipulation. A combination of manual external pressure of the axillary artery combined with internal tamponade effect from a 45 cm hydrophilic sheath was used with no immediate or...

متن کامل

Laparoscopic Cholecystectomy; closure versus non-closure of the fascial sheath opening of the sub-umbilical port site “10 mm”.

Background: Laparoscopic Surgery (LS) may be associated with many port site complications such as hernia, bleeding, infection, subcutaneous emphysema and ugly scars. Some of these complications are serious such as obstructed port site hernia . Rate of these complications is low depending  on size and site of the port incision, type of the trocar that it is used, the condition of  the patient a...

متن کامل

Incidence of radial artery occlusion in radial angiography compared with snuffbox angiography

Background: Transradial access is one of the main access techniques in angiography. This method is technically more difficult as it is associated with radial artery occlusion. Radial artery cannulation from the dorsal surface of the hand in the snuffbox area has been introduced as a suitable solution to overcome some of the disadvantages of the standard radial artery method. This study was cond...

متن کامل

Iatrogenic catheter sheath shearing during radial artery cannulation

Corresponding author: Il-Seok Kim, M.D., Department of Anesthesiology and Pain Medicine, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, 445, Gil-dong, Gangdong-gu, Seoul 134-010, Korea. Tel: 82-2-2224-2659, Fax: 82-2-474-0956, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (...

متن کامل

Pre-closure of Large-Sized Arterial Access Sites in Adults Undergoing Transcatheter Structural Interventions

INTRODUCTION Patients undergoing structural heart interventions often require large-sized sheath insertion into femoral arteries and veins. Clinical outcome data on the use of suture-mediated devices for large femoral arterial access in structural heart interventions is limited. We assessed the efficacy of the Perclose™ (Abbott Vascular Devices, Santa Clara, CA, USA) suture-mediated device usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Cardiology and angiology: an international journal

سال: 2021

ISSN: ['2347-520X']