Low-energy broad-beam photon shielding data for constituents of concrete

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low‐energy broad‐beam photon shielding data for constituents of concrete

The ability of concrete to attenuate ionizing radiation intensity is assessed using its linear or mass attenuation coefficient. In this work, the broad-beam linear and mass attenuation coefficients of different types of soils and cements used for making concrete were measured at different photon energies (60-1333 keV), nearly spanning the diagnostic photon energy range, using a NaI detector. Th...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

Production of a novel high strength heavy concrete using tourmaline and galena for neutron and photon radiation shielding

Background: High density concrete is extensively used for efficient radiation attenuation in radiotherapy rooms and nuclear reactors. Over the past eight years, some efficient galena-based concrete samples for shielding X or gamma rays was produced. The goal of this study was to produce a novel high density concrete against neutron and photon radiations using tourmaline and galena. Materials an...

متن کامل

A Comparative Study of the Construction of Positron Emission Tomography/Computed Tomography Facilities in Three South African Hospitals

Introduction: Development of higher energy modalities such as positron emission tomography/computed tomography (PET/CT), has led to more complex shielding problems. This is due to several factors, such as the radiopharmaceutical relatively high-administered activity, high patient throughput, and high energies of 511 kilo-electron volt (keV) positron annihilation photon...

متن کامل

A comparison of methods for monitoring photon beam energy constancy

In extension of a previous study, we compared several photon beam energy metrics to determine which was the most sensitive to energy change; in addition to those, we accounted for both the sensitivity of each metric and the uncertainty in determining that metric for both traditional flattening filter (FF) beams (4, 6, 8, and 10 MV) and for flattening filter-free (FFF) beams (6 and 10 MV) on a V...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Clinical Medical Physics

سال: 2012

ISSN: 1526-9914

DOI: 10.1120/jacmp.v13i2.3525