Low field magnetic response of the non-centrosymmetric superconductor YPtBi
نویسندگان
چکیده
منابع مشابه
S-wave pairing symmetry in non-centrosymmetric superconductor Re3W
The alloys of non-centrosymmetric superconductor, Re3W, which were reported to have an α-Mn structure [P. Greenfield and P. A. Beck, J. Metals, N. Y. 8, 265 (1959)] with Tc = 9 K were prepared by arc melting. The ac susceptibility and low-temperature specific heat were measured on these alloys. It is found that there are two superconducting phases coexisting in the samples with Tc1 ∼ 9 K and Tc...
متن کاملMagnetic field dependence of the superconducting gap node topology in non-centrosymmetric CePt3Si
Non-centrosymmetric superconductors, such as CePt3Si and Li2PtB2, are believed to have a line node in the energy gap arising from coexistence of s-wave and p-wave pairing. Using as an example CePt3Si we show that a weak c-axis magnetic field will remove this line node, since it has no topological stability against time-reversal symmetry breaking perturbations. Conversely a field in the a − b pl...
متن کاملCentrosymmetric and pseudo-centrosymmetric structures refined as non-centrosymmetric.
The behaviour of the Flack parameter for centrosymmetric and pseudo-centrosymmetric crystal structures based on crystal structures published as being non-centrosymmetric is presented. It is confirmed for centrosymmetric structures that the value obtained for the Flack parameter is critically dependent on the Friedel coverage of the intensity data, approaching 0.5 for a coverage of 100% and stic...
متن کاملObservation of Time-Reversal Symmetry Breaking in the Non-Centrosymmetric Superconductor Re6Zr
If you believe this document infringes copyright then please contact the KAR admin team with the take-down information provided at http://kar.kent.ac.uk/contact.html Citation for published version Singh, R P and Hillier, Adrian D and Mazidian, Bayan and Quintanilla, Jorge and Annett, James F and Paul, D McK and Balakrishnan, G and Lees, M R (2014) Detection of Time-Reversal Symmetry Breaking in...
متن کاملThe Measurement of Low Frequency Magnetic Field of Two Kinds of GSM900 Mobile Phone
Introduction: The use of mobile communication systems has dramatically increased over the past decade. Although many studies have been performed to determine the effect of radio frequency (RF) but less attention has been paid to the possible biological impact of exposure to extremely low frequency (ELF) components. The objective of this study is two folds. One is to design the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Solid State Communications
سال: 2014
ISSN: 0038-1098
DOI: 10.1016/j.ssc.2013.12.010