LV volumes and EF by echo.

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference Ranges for LVEF and LV Volumes

Electrocardiographic gating is increasingly used for 82Rb cardiac PET/CT, but reference ranges for global functional parameters are not well defined. We sought to establish reference values for left ventricular ejection fraction (LVEF), end systolic volume (ESV), and end diastolic volume (EDV) using 4 different commercial software packages. Additionally, we compared 2 different approaches for t...

متن کامل

NEW ECHO LV MEASUREMENT RECOMMENDATIONS/Crawford

SM, Marks RA, Jarmakani JM: Accuracy of echocardiography in assessing left ventricular dimensions and volume. Circulation 57: 699, 1978 12. Burggraf GW, Parker JO: Left ventricular volume changes after amyl nitrite and nitroglycerin in man as measured by ultrasound. Circulation 49: 136, 1974 13. Redwood DR, Henry WL, Epstein SE: Evaluation of the ability of echocardiography to measure acute alt...

متن کامل

Simultaneous LV and RV volumes by conductance catheter: effects of lung insufflation on parallel conductance.

One aspect in the measurement of ventricular volume using the conductance catheter technique is the assessment of parallel electrical conductivity of structures extrinsic to the ventricular blood pool. Because it is sometimes necessary to make volume measurements during ventilation or spontaneous respiration, the extent to which parallel conductance may vary with lung insufflation was investiga...

متن کامل

Quantification of LV Volumes with 4D Real-Time Echocardiography

This paper presents a new 4D (3D + Time) expansion of echocardiographic volumes on complex exponential wavelet-like basis functions called Brushlets [1]. Brushlet functions offer good localization in time and frequency and decompose a signal into distinct patterns of oriented textures, invariant to intensity and contrast range. Automatic left ventricle (LV) endocardial border detection is carri...

متن کامل

Statistical agreement of left ventricle measurements using cardiac magnetic resonance and 2D echocardiography in ischemic heart failure

BACKGROUND The aim of this study was to compare cardiac magnetic resonance imaging (CMR) with 2-dimensional echocardiography (2D echo) in the assessment of left ventricle (LV) function parameters and mass in patients with ischemic heart disease and severely depressed LV function. Although 2D echo is commonly used to assess LV indices, CMR is the state-of-the-art technique. Agreement between the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Circulation

سال: 1980

ISSN: 0009-7322,1524-4539

DOI: 10.1161/01.cir.61.5.1056