LYSO based precision timing calorimeters
نویسندگان
چکیده
منابع مشابه
Monitoring LSO/LYSO Crystal Based Calorimeters
Precision light monitoring is important for keeping excellent energy resolution promised by LSO/LYSO crystals in severe radiation environment. In this paper, we report an investigation on the wavelength choice for monitoring LYSO crystal based calorimeters. Gamma-ray induced absorption and light output loss were measured for 20 cm long crystals from five different vendors. Monitoring sensitivit...
متن کاملCalorimeters for Precision Timing Measurements in High Energy Physics
Current and future high energy physics particle colliders are capable to provide instantaneous luminosities of 1034 cm-2s-1 and above. The high center of mass energy, the large number of simultaneous collision of beam particles in the experiments and the very high repetition rates of the collision events pose huge challenges. They result in extremely high particle fluxes, causing very high occu...
متن کاملThe timing system for the CDF electromagnetic calorimeters
We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high-energy photons to verify that the photon is in time with the event collision, to reject cosmic-ray and beam-halo backgrounds, and to allow direct searches for new, heavy, long-lived ...
متن کاملGps Precision Timing at Cern
For the past decade, the Global Positioning System (GPS) has been used to provide precise time, frequency and position co-ordinates world-wide. Recently, equipment has become available specialising in providing extremely accurate timing information, referenced to Universal Time Co-ordinates (UTC). This feature has been used at CERN to provide time of day information for systems that have been i...
متن کاملTiming precision in circle drawing does not depend on spatial precision of the timing target.
The authors manipulated the width of a timing target in continuous circle drawing to determine whether a more stringent spatial-timing criterion would produce an increase in participants' (N = 30) temporal variability. They also examined the effect of the computational method of determining cycle duration. There was no effect of spatial precision on temporal variability in circle drawing, and t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2017
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/928/1/012023