Macromolecular Crystallography at Chess
CHESS activity report F many years, most synchrotron stations for crystallography, such as CHESS A1, used X-ray sensitive film as the primary detector and xray radiation at about 8 keV (1.5 Å). Two years ago CHESS constructed station F1 on a wiggler line that is tuneable from about 7-14 keV. In practice, this station operates with a standard energy of 0.91 Å. The benefits of using higher energi...
متن کاملMacromolecular crystallography beamline X25 at the NSLS
Beamline X25 at the NSLS is one of the five beamlines dedicated to macromolecular crystallography operated by the Brookhaven National Laboratory Macromolecular Crystallography Research Resource group. This mini-gap insertion-device beamline has seen constant upgrades for the last seven years in order to achieve mini-beam capability down to 20 µm × 20 µm. All major components beginning with the ...
متن کاملSerial snapshot crystallography for materials science with SwissFEL
New opportunities for studying (sub)microcrystalline materials with small unit cells, both organic and inorganic, will open up when the X-ray free electron laser (XFEL) presently being constructed in Switzerland (SwissFEL) comes online in 2017. Our synchrotron-based experiments mimicking the 4%-energy-bandpass mode of the SwissFEL beam show that it will be possible to record a diffraction patte...
متن کاملMacromolecular Crystallography and Structural Biology Databases at NIST
In the late 1970s, macromolecular crystallography at NIST began with collaboration between NIST and NIH to establish a single-crystal neutron diffractometer. This instrument was constructed and employed to solve a number of crystal structures: bovine ribonuclease A, bovine-ribonuclease-uridine vanadate complex, and porcine insulin. In the mid 1980s a Biomolecular Structure Group was created est...
متن کاملFacilities for macromolecular crystallography at the Helmholtz-Zentrum Berlin
Three macromolecular crystallography (MX) beamlines at the Helmholtz-Zentrum Berlin (HZB) are available for the regional, national and international structural biology user community. The state-of-the-art synchrotron beamlines for MX BL14.1, BL14.2 and BL14.3 are located within the low-β section of the BESSY II electron storage ring. All beamlines are fed from a superconducting 7 T wavelength-s...