MAGIC-fgel dosimetry for clinical electron beam

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electron Beam Dosimetry in Heterogeneous Phantoms Using a MAGIC Normoxic Polymer Gel

Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...

متن کامل

Two New Parallel-plate Ionization Chambers for Electron Beam Dosimetry

-Two parallel-plate ionization chambers were projected, constructed and evauated for use in high energy electron beams. They were constructed using the two plastic materials recommended for clinical dosimetry protocols, i.e. acrylic and polystyrene. Both chambers have cylindrical shape with entrance windows in aluminized Mylar and they are open to the air. The acrylic chamber has a 2 mm air gap...

متن کامل

Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25.

The goal of Task Group 25 (TG-25) of the Radiation Therapy Committee of the American Association of.Physicists in Medicine (AAPM) was to provide a methodology and set of procedures for a medical physicist performing clinical electron beam dosimetry in the nominal energy range of 5-25 MeV. Specifically, the task group recommended procedures for acquiring basic information required for acceptance...

متن کامل

Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry.

The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic-therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water-to-plastic ionization conversion factor k(pl) for PW and PWDT was computed for several commonly used Farmer-type ionization chambers with different wall materials ...

متن کامل

Characterization of a gated fiber-optic-coupled detector for application in clinical electron beam dosimetry.

PURPOSE Assessment of the fundamental dosimetric characteristics of a novel gated fiber-optic-coupled dosimetry system for clinical electron beam irradiation. METHODS The response of fiber-optic-coupled dosimetry system to clinical electron beam, with nominal energy range of 6-20 MeV, was evaluated for reproducibility, linearity, and output dependence on dose rate, dose per pulse, energy, and...