Magic Frequencies for Cesium Primary-Frequency Standard
نویسندگان
چکیده
منابع مشابه
Magic frequencies for cesium primary-frequency standard.
We consider microwave hyperfine transitions in the ground state of cesium and rubidium atoms which are presently used as the primary and the secondary frequency standards. The atoms are confined in an optical lattice generated by a circularly polarized laser field. We demonstrate that applying an external magnetic field with appropriately chosen direction may cancel dynamic Stark frequency shif...
متن کاملThe NIST Optically Pumped Cesium Frequency Standard
The National Institute of Standards and Technology is developing an optically pumped, cesium-beam primary frequency standard. The design follows from an analysis of systematic errors found in cesium beam standards. The details of the design, performance of major subsystems, and preliminary tests of the standard are presented.
متن کاملOptically Pumped Cesium-beam Frequency Standard for Gps-i11
We describe an optically pumped cesium-beam frequency standard under development for deployment on the GPS-III satellite constellation. The objective of the project is to demonstrate the feasibility of a space quulifikd optically pumped cesium-beam frequency standard exhibiting a short-term stability of cry (r < 6 x f-ln with lifetime and reliability comparable to that of the current GPS-IIF ce...
متن کاملDesign of Gradient Magnet System for Cesium Frequency Standard
The design process and the magnetic measurements 011 a permanent magnet asymmetric dipole to be used for magnetic selection in a Cs beam frequency standard is presented Tbe design target is to create a magnetic induction gradient of 50 Tlm in a zone extending 10 mm in width and 50 mm in length. The computer aided design process is outlined and design predictions are compared with measurements o...
متن کاملHigh Homogeneity Solenoidal Magnet for Cesium Frequency Standard
In Cs frequency standards a zone of highly uniform magnetic flus density, lower in value of 0.1 T, is required The magnetic homogeneity value is tied to the overall accuracy of the standard and, for an accuracy of a design value 1 p.p.m. is required. For this purpose a resistive solenoid 700 mm long with a bore radius of 32.5 mm has been designed and built. This paper reports the design process...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review Letters
سال: 2008
ISSN: 0031-9007,1079-7114
DOI: 10.1103/physrevlett.101.220801