Manipulative and inherent errors in anti-D quantitation using the AutoAnalyzer.

The limits of accuracy for the quantitation of anti-D using the AutoAnalyzer have been reduced from +/- 26% with manually prepared dilutions to +/- 14% using an automatic pipette, as expressed by the 95% confidence limits. The error inherent in the AutoAnalyzer was estimated to contribute +/- 10% to the overall error. Problems associated with the reproducibility of this method for anti-D quanti...

متن کامل

The adverse effect of bromelin in anti-D quantitation using the AutoAnalyzer.

With eight of 32 sera significantly higher estimations of anti-D concentration were obtained when test cells premodified with bromelin were used instead of bromelin as a reagent added to the reaction manifold. With one serum the difference in estimation, using the two techniques, revealed a ten-fold discrepancy. The consequences of these findings are discussed in relation to the use of the Auto...

متن کامل

Inherent Errors in the Quantitation of Dialysis Delivery: Implications For CAPD and Daily Hemodialysis.

When compared to intermittent dialysis, the theoretical advantages of continuous dialysis may be less important than its practical disadvantage: the inability to accurately quantify dialysis. With intermittent dialysis the change in blood urea nitrogen over the course of the treatment allows the ratio of K (urea clearance) to V (volume of distribution of urea or total body water) to be determin...

متن کامل

ASBT Anti-D quantitation working party

not available at time of printing Improving appropriateness of blood transfusion in the 21st century Mark A Popovsky Haemonetics Corporation, Braintree, MA Although blood has never been safer, fatal and non-fatal complications still occur. Data from the literature indicates that red cell & plasma components are frequently used inappropriately with reports of 20 60% non-indicated transfusions. S...

متن کامل

collocation errors in translations of the holy quran

the present study aims at identifying, classifying and analyzing collocation errors made by translators of the holy quran into english.findings indicated that collocationally the most acceptablt translation was done by ivring but the least appropriate one made by pickthall.

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Pathology

سال: 1972

ISSN: 0021-9746

DOI: 10.1136/jcp.25.3.198