Manually operated low-coherence interferometer for optical information hiding
نویسندگان
چکیده
منابع مشابه
Common-path interferometer for frequency-domain optical coherence tomography.
A Michelson-type spectral interferometer that uses a common beam path for the reference and the sample arms is described. This optical arrangement is more compact and stable than the more commonly used dual-arm interferometer and is well suited for frequency-domain optical coherence tomography of biological samples. With a 16-bit CCD camera, the instrument has sufficient dynamic range and resol...
متن کاملLow Dispersion Integrated Michelson Interferometer on Silicon on Insulator for Optical Coherence Tomography
We present an integrated silicon Michelson interferometer for OCT fabricated with wafer scale deep UV lithography. Silicon waveguides of the interferometer are designed with GVD less than 50 ps/nm.km. The footprint of the device is 0.5 mm x 3 mm. The effect of sidewall roughness of silicon waveguides has been observed, possible solutions are discussed.
متن کاملTechnology of manually operated sampler pipets.
We have evaluated the performance of manually operated sampler pipets. Twenty-four instruments of various construction, manufacture, and delivery volume were evaluated. Pipet-delivered water and serum were repeatedly weighed under controlled environmental conditions, and precision and accuracy assessed. The pipets often failed to meet the manufacturer’s stated tolerance limits. Consumers should...
متن کاملQuadrature Mach–Zehnder interferometer with application in optical coherence tomography
A novel quadrature interferometer based on Mach–Zehnder configuration and a 3 × 3 fibre coupler is presented. Measurements showing instantaneous extraction of both real and complex parts of the interferometric signal are described. The features of this quadrature interferometric platform are discussed with a focus on signal-to-noise ratio and optical power handling.
متن کاملDouble common-path interferometer for flexible optical probe of optical coherence tomography
A flexible curled optical cord is useful for a common-path optical coherence tomography (OCT) system because a bending-insensitive arbitrary length can be chosen for the endoscopic imaging probe. However, there has been a critical problem that the partial reflector needs to be placed in between the sample and the objective lens. It limits the structure design of optical probe and leads to a low...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2006
ISSN: 1094-4087
DOI: 10.1364/oe.14.009421