Many-isocenter optimization for robotic radiotherapy
نویسندگان
چکیده
منابع مشابه
Dosimetric Comparison of Two Craniospinal Radiotherapy Techniques for Treatment Optimization
Introduction: Orthogonal radial fields are those in which the central axes are perpendicular to each other. An example of these orthogonal fields is the set of craniospinal orthogonal fields that are used for radiotherapy of medulloblastoma. Craniospinal radial fields consist of two parallel-opposed fields for brain exposure and one or two posterior spinal fields for spinal cord exposure. The m...
متن کاملSU-F-T-547: Off-Isocenter Winston-Lutz Test for Stereotactic Radiosurgery/stereotactic Body Radiotherapy.
PURPOSE To perform a quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter during the single-isocenter technique in linear accelerator-based SRS/SBRT procedure to treat multiple lesions. METHODS We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here ...
متن کاملModular Optimization for Robotic Explorers
Robotic explorers perform multiple tasks and have multiple constraints to optimize. Planning the best sequence of tasks requires information about how a given sequence will affect the constraints and goals of the explorer. Modules for all constraints and goals are created, each one of which evaluates a given plan from its point of view. The resulting values of the modules are then combined in a...
متن کاملOptimization Algorithm for Single-Isocenter VMAT Stereotactic Radiosurgery for Multiple Brain Metastases
Objectives: Developing an optimal Stereotactic radiosurgery (SRS) plan for multiple brain metastases can be a labor intensive process. Single-isocenter multi-arc volumetrically modulated arc therapy (VMAT) has been used as an SRS technique, in which a Linear Accelerator (Linac) delivers targeted radiation along multiple arc angles as it rotates around the isocenter. Standardized arc angles with...
متن کاملRobotic Microsurgery Optimization
The increased application of the da Vinci robotic platform (Intuitive Surgical Inc.) for microsurgery has led to the development of new adjunctive surgical instrumentation. In microsurgery, the robotic platform can provide high definition 12×-15× digital magnification, broader range of motion, fine instrument handling with decreased tremor, reduced surgeon fatigue, and improved surgical product...