Mass transfer between isobutanol and water in concurrent flow through a packed column
نویسندگان
چکیده
منابع مشابه
Heat Transfer in a Column Packed With Spheres
The purpose of the study is to investigate average and local surface heat transfer coefficients in a cylinder packed with spheres. Here the term «local» applies to a single sphere within the bed. Averages are derived from the sixteen different spheres that were instrumented and distributed throughout the bed. The experimental technique consisted of introducing a step - wise change in the temper...
متن کاملMass Transfer in a Gas-Solid Packed Column at Trickle Flow
The hetght of an ovemll transfer unat has been evaluated m a gas-solid packed column at tnckle flow by measunng column performance during steady state adsorption expertments. Results have been anterpreted wtth an extmctton model mass transfer and axial dispersaon ua both phases Usmg Bodenstem numbers for the gas and solid phases from a previous investagation the hetght of a true transfer untt h...
متن کاملTurbulent Events and Gas-Side Mass Transfer Coefficients in a Wavy Air-Water Stratified Flow
Turbulence structure on the gas side of a wavy stratified flow was experimentally investigated in a near horizontal 18.7 cm (H) 10 cm (W) 5.5m (L) rectangular duct.By applying the Variable Interval Time Averaging (VITA) technique to the hot wire anemometer measurements frequency of occurrence of turbulent events were detected near the air-water interface. Experimental results showed that fr...
متن کاملFlow Analysis Heat and Mass Transfer in a Room
This reports the study on the flow behaviour, heat transfer and contamination distribution in a room. For this purpose the 3-D incompressible Navier-Stokes equations, energy equation and a mass transfer equation which model the concentration of contamination have been applied. For turbulence simulation the two equation standard k- turbulence model was employed. By means of SIMPLE algorithm the...
متن کاملGas-solid Trickle Flow Hydrodynamics in a Packed Column
The pressure gradient and the static and the dynamic hold-up have been measured for a system consisting ofa Fluid Cracking Catalyst (FCC) of 30-150 x 10m6 m diameter, trickling over a packed bed and with a gas streaming in countercurrent flow. The experiments were carried out at ambient conditions using a glass column of 25 x 10 ~’ m diameter. The packing material consisted of 8 x 8 x 3 mm cera...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: AIChE Journal
سال: 1961
ISSN: 0001-1541,1547-5905
DOI: 10.1002/aic.690070206