Mass transfer in a gas—solid packed column at trickle flow
نویسندگان
چکیده
منابع مشابه
Mass Transfer in a Gas-Solid Packed Column at Trickle Flow
The hetght of an ovemll transfer unat has been evaluated m a gas-solid packed column at tnckle flow by measunng column performance during steady state adsorption expertments. Results have been anterpreted wtth an extmctton model mass transfer and axial dispersaon ua both phases Usmg Bodenstem numbers for the gas and solid phases from a previous investagation the hetght of a true transfer untt h...
متن کاملGas-solid Trickle Flow Hydrodynamics in a Packed Column
The pressure gradient and the static and the dynamic hold-up have been measured for a system consisting ofa Fluid Cracking Catalyst (FCC) of 30-150 x 10m6 m diameter, trickling over a packed bed and with a gas streaming in countercurrent flow. The experiments were carried out at ambient conditions using a glass column of 25 x 10 ~’ m diameter. The packing material consisted of 8 x 8 x 3 mm cera...
متن کاملHydrodynamic Behaviour of a Gas-Solid Counter-current Packed Column at Trickle Flow
Trickle flow of a more or less fluidized catalyst through a packed column is a promising new gas-solid counter-current operation. The hydrodynamic behaviour of such a column, filled with dumped PALL rings, has been investigated, while some results have been obtained with RASCHIG rings and cylindrical screens as packing. The solid used was a microspherical catalyst carrier. Pressure drop, hold-u...
متن کاملHeat Transfer in a Column Packed With Spheres
The purpose of the study is to investigate average and local surface heat transfer coefficients in a cylinder packed with spheres. Here the term «local» applies to a single sphere within the bed. Averages are derived from the sixteen different spheres that were instrumented and distributed throughout the bed. The experimental technique consisted of introducing a step - wise change in the temper...
متن کاملFlow Analysis Heat and Mass Transfer in a Room
This reports the study on the flow behaviour, heat transfer and contamination distribution in a room. For this purpose the 3-D incompressible Navier-Stokes equations, energy equation and a mass transfer equation which model the concentration of contamination have been applied. For turbulence simulation the two equation standard k- turbulence model was employed. By means of SIMPLE algorithm the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Chemical Engineering Journal
سال: 1979
ISSN: 0300-9467
DOI: 10.1016/0300-9467(79)80011-8