Mattauch-Herzog award
نویسندگان
چکیده
منابع مشابه
Compatibility of Spatially Coded Apertures with a Miniature Mattauch-Herzog Mass Spectrograph.
In order to minimize losses in signal intensity often present in mass spectrometry miniaturization efforts, we recently applied the principles of spatially coded apertures to magnetic sector mass spectrometry, thereby achieving increases in signal intensity of greater than 10× with no loss in mass resolution Chen et al. (J. Am. Soc. Mass Spectrom. 26, 1633-1640, 2015), Russell et al. (J. Am. So...
متن کاملMattauch-Herzog Type Mass Spectrograph with a Two Stage Electrostatic Field
It is very complicated to calculate the secondorder aberrations of complex analyser systems and mistakes are liable to be made. Even if the matrix method is used the tediousness of the calculation is not altered. The usefulness of the matrix representation comes from the fact that the over-all transfer matrix of the total system is easily written as a product of the transfer matrices of various...
متن کاملDraft Shai Herzog
This memo presents a set of extensions for supporting generic policy based admission control in RSVP. It should be perceived as an extension to the RSVP functional specifications [RSVP] These extensions include the standard format of POLICY_DATA objects, and a description of RSVP’s handling of policy events. This document does not advocate particular policy control mechanisms; however, a Router...
متن کاملDagmar Herzog : Sex after Fascism
University Press. All rights reserved. No part of this book may be reproduced in any form by any electronic or mechanical means (including photocopying, recording, or information storage and retrieval) without permission in writing from the publisher, except for reading and browsing via the World Wide Web. Users are not permitted to mount this file on any network servers. Introduction WHAT IS T...
متن کاملCharacterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source.
A Mattauch-Herzog geometry mass spectrograph (MHMS) has been equipped with a novel array detector, the focal plane camera (FPC). The FPC consists of an array of gold Faraday cups, each coupled to its own integrator, with interrogation of the integrators performed by a multiplexer. The initial coupling of this instrument with a pin-type glow discharge source has provided limits of detection in t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Rapid Communications in Mass Spectrometry
سال: 1989
ISSN: 0951-4198,1097-0231
DOI: 10.1002/rcm.1290030715