Maximum Efficiency STEM Phase Contrast Imaging

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maximum Efficiency STEM Phase Contrast Imaging

Various bright-field (BF) imaging modes are available in scanning transmission electron microscopy (STEM). The mode equivalent to phase contrast imaging in conventional high-resolution transmission electron microscopy (TEM) involves a detector about an order of magnitude smaller than the convergence angle of the probe. This means a large proportion of the incident electrons go to waste as most ...

متن کامل

Pixelated detectors and improved efficiency for magnetic imaging in STEM differential phase contrast.

The application of differential phase contrast imaging to the study of polycrystalline magnetic thin films and nanostructures has been hampered by the strong diffraction contrast resulting from the granular structure of the materials. In this paper we demonstrate how a pixelated detector has been used to detect the bright field disk in aberration corrected scanning transmission electron microsc...

متن کامل

4D STEM: High efficiency phase contrast imaging using a fast pixelated detector

Phase contrast imaging is widely used for imaging beam sensitive and weak phase objects in electron microscopy. In this work we demonstrate the achievement of high efficient phase contrast imaging in STEM using the pnCCD, a fast direct electron pixelated detector, which records the diffraction patterns at every probe position with a speed of 1000 to 4000 frames per second, forming a 4D STEM dat...

متن کامل

Phase contrast X - ray imaging

In the last decade X-ray imaging based on phase contrast greatly advanced thanks to the use of unmonochromatic synchrotron hard X-rays. The recent advances are going beyond microradiology and microtomography to reach nanometre scale. This paper reviews basic theory and selected applications to biomedical and materials sciences. The forthcoming improvements in phase contrast X-ray imaging will l...

متن کامل

Phase-Contrast X-ray imaging

Virtually all X-rays imaging in a medical or biological context is performed by measuring differences in the attenuation of X-rays by the tissues. The material properties are inferred from the differences in the number of photons detected at the end of defined paths in the sample. Naturally then this form of X-ray imaging concentrates almost entirely on the particle side of X-ray behaviour. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Microscopy and Microanalysis

سال: 2014

ISSN: 1431-9276,1435-8115

DOI: 10.1017/s1431927614003638